5
104782
OWNER’S MANUAL
STORAGE
CAUTION: Disconnect heater
from propane supply tank(s).
MAINTENANCE
1. Store propane tank(s) in safe manner.
Refer to Chapter 5 of Standard for
Storage and Handling of Liquefied Pe-
troleum Gases, ANSI/NFPA 58 and/or
CAN/CGA B149.2. Follow all local
codes. Always store propane tanks
outdoors.
2. Place plastic cover caps over brass fit-
tings on valve inlet and hose/regulator
assembly.
3. Store in a dry, clean, and safe place.
WARNING:
• Never attempt to service heater
while it is connected to pro-
pane supply, operating, or hot.
Severe burns can occur.
• Keep heater clear and free from
combustible materials, gaso-
line, and other flammable va-
pors and liquids.
• Do not block the flow of com-
bustion or ventilation air.
REPLACEMENT
PARTS
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If
they can’t supply original replacement part(s),
call DESA Industries at 1-905-826-8010.
When calling DESA Industries, have ready:
• your name
• your address
• model and serial numbers of your heater
• how heater was malfunctioning
• purchase date
In most cases, we will ask you to return the
defective part to the factory.
WARNING: Use only original
replacement parts. This heater
must use design-specific parts.
Do not substitute or use generic
parts. Improper replacement
parts could cause serious or fa-
tal injuries. This will also protect
your warranty coverage for parts
replaced under warranty.
SPECIFICATIONS
Output Rating (Btu/Hr)
High 200,000
Low 100,000
Fuel Propane Vapor Only
Fuel Consumption
Liters (Gallons)/Hour 4.13 (1.09) minimum - 8.29 (2.19) maximum
Kilogram (Pounds)/Hour 2.1 (4.64) minimum - 4.2 (9.28) maximum
Supply Pressure To Regulator
Maximum 1380 kPa (200 psi)
Minimum 138 kPa (20 psi)
(for input adjustment)
Manifold Pressure
High 36 kPa (5.2 psi)
Low 47 kPa (6.9 psi)
Weight
Heater Weight 7.3 kg (16 lbs)
Shipping Weight 9 kg (20 lbs)
Size - L x W x H 76.2 x 38.1 x 40.6 cm (30 x 15 x 16 in)
Minimum Temperature -29 °C (-20° F)
Surrounding Air Temperature
1. Keep heater clean. Clean heater annu-
ally or as needed to remove dust and
debris. If heater is dirty or dusty, clean
heater with a damp cloth. Use house-
hold cleaners on difficult spots.
2. Inspect heater before each use. Check
connections for leaks. Apply mixture
of liquid soap and water to connections.
Bubbles forming show a leak. Correct
all leaks at once.
3. Inspect hose/regulator assembly before
each use. If hose is highly worn or cut,
replace.
4. Have heater inspected yearly by a quali-
fied service agency.
PARTS NOT UNDER
WARRANTY
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call DESA Industries’ Parts Depart-
ment at 1-905-826-8010.
When calling DESA Industries, have ready:
• model number of your heater
• the replacement part number