OWNER’S MANUAL
PRODUCT
IDENTIFICATION
THEORY OF
OPERATION
The Fuel System: The hose/regulator
assembly attaches to the propane gas sup-
ply. This provides fuel to the heater.
The Ignition System: The piezo ignitor
lights the burner fuel supply.
The Automatic Control System: This
system causes the heater to shut down if the
flame goes out.
1. Remove all packing items applied to
heater for shipment. Keep plastic cover
caps (attached to valve inlet and hose/
regulator assembly) for storage.
2. Remove all items from carton.
3. Check all items for shipping damage.
If heater is damaged, promptly inform
dealer where you bought heater.
UNPACKING
Figure 1 - Product Identification
AT
PUSH
TO START
LO
HI
Hose/
Regulator
Assembly
Shell
Base
Piezo
Ignitor
Button
Ignitor
Electrode
Thermocouple
Valve
Inlet
Control Knob
Top
PROPANE SUPPLY
Propane gas and propane tank(s) are to be
furnished by the user.
Use this heater only with a propane vapor
withdrawal supply system. See Chapter 5 of
the Standard for Storage and Handling of
Liquefied Petroleum Gas, ANSI/NFPA 58
and/or CAN/CGA B149.2. Your local library
or fire department will have this booklet.
The amount of propane gas ready for use
from propane tanks varies. Two factors de-
cide this amount.
1. The amount of liquid propane gas in
tank(s)
2. The temperature of tank(s)
The chart below shows the minimum num-
ber of 45 kg (100 lb) tanks needed to run the
heater. Connect tanks together with a mani-
fold. Do not operate this product with any
tank smaller than 45 kg (100 lb).
Less gas is vaporized at lower temperatures.
You may need two or more 45 kg (100 lb.)
tanks or one larger tank in colder weather.
Your local propane gas dealer will help you
select the proper supply system. The mini-
mum surrounding air temperature rating for
each heater is -29°C (-20°F).
Average Number Of
Temperature °C (°F) Tanks
At Tank Location 45 kg (100 lb)
16° (60°)2
4° (40°)2
0° (32°)2
-6.7° (20°)2
-12° (10°)3
-18° (0°)3
VENTILATION
FRESH OUTSIDE AIR OPENING
REQUIREMENTS
HEATER SIZE OPENING
200,000 Btu/Hr .56 m
2
(6.0 ft
2
)
WARNING: Provide at least a
.56 m
2
(6 ft
2
) opening of fresh,
outside air while running heater.
If proper fresh, outside air venti-
lation is not provided, carbon
monoxide poisoning can occur.
Provide proper fresh, outside air
ventilation before running heater.