Desa LMFP33NR(B) Indoor Fireplace User Manual


 
www.desatech.com
119526-01A26
TROUBLESHOOTING
Continued
OBSERVED PROBLEM
Slight smoke or odor during initial
operation
Moisture/condensation noticed
on windows
Heater produces a whistling noise
when burners are lit
White powder residue forming
within burner box or on adjacent
walls or furniture
Remote does not function
Fireplace produces a clicking/
ticking noise just after burner is
lit or shut off
POSSIBLE CAUSE
1. Not enough air
2. Gas regulator defective
3. Residues from manufacturing
processes and logs curing
1. Not enough combustion/ven-
tilation air
1. Turning control knob to HI po-
sition when burners are cold
2. Air in gas line
3. Air passageways on heater
blocked
4. Dirty or partially clogged
burner orice(s)
1. When heated, vapors from
furniture polish, wax, carpet
cleaners, etc. may turn into
white powder residue
1. Battery is not installed. Bat-
tery power is low
1. Metal expanding while heating
or contracting while cooling
REMEDY
1. Check burner for dirt and
debris. If found, clean burner
(see Cleaning and Mainte-
nance, page 23)
2. Replace gas control
3. Problem will stop after a few
hours of operation
1. Refer to Air for Combustion
and Ventilation requirements
(page 5)
1. Turn control knob to LO
position and let warm up for
a minute
2. Operate burners until air is
removed from line. Have gas
line checked by local natural
or propane/LP gas company
3. Observe minimum installation
clearances (see page 9)
4. Clean burners (see Cleaning
and Maintenance, page 23)
or replace burner orice(s)
1. Turn heater off when using
furniture polish, wax, carpet
cleaners or similar products
1. Replace 9-volt batteries in
receiver and remote control
1. This is normal with most heat-
ers. If noise is excessive, contact
qualied service person