Desa GA3700 Indoor Fireplace User Manual


 
www.desatech.com
113109-01G 5
LOCAL CODES
Install and use replace with care. Follow all
local codes. In the absence of local codes,
use the latest edition of The National Fuel
Gas Code, ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
State of Massachusetts: The installation
must be made by a licensed plumber or
gas tter in the Commonwealth of Mas-
sachusetts.
Sellers of unvented propane or natural
gas-fired supplemental room heaters
shall provide to each purchaser a copy of
527 CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for
bedroom and bathroom installation in
the Commonwealth of Massachusetts.
UNPACKING
CAUTION: Do not remove the




1. With utility knife, cut the carton all the way
around above the staples on the bottom
tray. Lift the carton off the heater. Remove
packing.
Note: The hood is located in the packing
on the right hand side of the heater front.
Lift the heater off the bottom tray.
2. Locate two screws above top corners of
the replace screen. Remove and discard
these screws. Lift replace screen up and
pull out to remove.
3. Remove protective packaging applied to
logs, log base assembly and replace.
4. Remove fireplace hood from carton
insert.
5. Check all items for any shipping damage.
If damaged, promptly inform dealer where
you bought replace.
PRODUCT FEATURES
OPERATION
This vent-free replace is clean burning. It re-
quires no outside venting. There is no heat loss
out a vent or up a chimney. Heat is generated by
realistic ames. When used without the blower,
replace requires no electricity making it ideal
for emergency backup heat. This heater is de-
signed for vent-free operation. It has been tested
and approved to ANSI Z21.11.2 standard for
unvented heaters. State and local codes in some
areas prohibit the use of vent-free heaters.
SAFETY DEVICE
This replace has a pilot with an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS/pilot is a required feature
for vent-free room heaters. The ODS/pilot
system shuts off the replace if there is not
enough fresh air.
PIEZO IGNITION SYSTEM
This replace has a piezo ignitor. This sys-
tem requires no matches, batteries or other
sources to light replace.
OPTIONAL REMOTE CONTROL UNITS
There are four optional remote controls that
can be purchased separately for this log
heater:
wall switch
wall thermostat
hand-held ON/OFF remote
hand-held thermostat remote
See Accessories, page 34.
OPTIONAL BLOWER ASSEMBLY


This replace accepts an optional blower as-
sembly (not included). The GA3700T Series
blower operates thermostatically and features
a variable speed control. The GA3700 Series
blower operates manually and also features a
variable speed control. The blower circulates
heated air from the replace into the room.
See Accessories, page 34.