Desa GA3700 Indoor Fireplace User Manual


 
www.desatech.com
113109-01G 9
Figure 5 - Installing Hood to Firebox
Note: Your replace is designed to be used in
zero clearance installations. Wall or framing ma-
terial can be placed directly against any exterior
surface on the rear, sides or top of your replace,
except where standoff spacers are integrally at-
tached. If standoff spacers are attached to your
replace, these spacers can be placed directly
against wall or framing materials.
Use the dimensions shown for rough openings
to create the easiest installation. See Built-In
Fireplace Installation, page 12.
IMPORTANT: Vent-free heaters add moisture
to the air. Although this is benecial, installing
replace in rooms without enough ventilation
air may cause mildew to form from too much
moisture. See Air for Combustion and Ventila-
tion, page 6.
IMPORTANT: Make sure the replace is level.
If replace is not level, log set will not work
properly.

Use the correct gas type (natural or propane/
LP) for your replace. If your gas supply is not
correct, do not install replace. Call dealer
where you bought replace for proper type
replace.



-






This replace accepts a blower assembly with
an electrical cord. The electrical cord is ve feet
in length. You must locate replace within reach
of a 120 volt grounded electrical outlet. If not,
you must install an electrical outlet within reach
of replace power cord. The GA3555 outlet
accessory is used for built-in applications with
blower accessory installed.
INSTALLING HOOD
Install hood to top of rebox as shown in
Figure 5. Use 3 Phillips screws provided.
INSTALLATION
Continued
Figure 6 - Assembling Perimeter Trim
Side Trim
Top
Trim
Slot
Mitered
Edge
Slot
Shim
Set Screws
Adjusting
Plate
ASSEMBLING AND ATTACHING
OPTIONAL PERIMETER TRIM

IMPORTANT: If you are recessing the re-
box in a wall, do not attach perimeter trim at
this time. See Built-In Fireplace Installation,
page 12.
Note: The instructions below show assembling
and attaching perimeter trim to replace.
1. Remove packaging from three pieces of
perimeter trim.
2. Locate four perimeter screws, two adjust-
ing plates with set screws and two shims
in the hardware packet.
3. Align shim under adjusting plate as shown
in Figure 6.
4. Slide one end of adjusting plate/shim in
slot on mitered edge of top perimeter trim
(see Figure 6).
5. Slide other end of adjusting plate/shim in
slot on mitered edge of side perimeter trim
(see Figure 6).
6. While rmly holding edges of perimeter trim
together, tighten both set screws on the
adjusting plate with slotted screwdriver.