www.desatech.com
108382-01G10
14"
Min.
Combustible
Material
Noncombustible Material
You must have noncombustible material(s) above
the replace opening. Noncombustible materials
(such as slate, marble, tile, etc.) must be at least
1/2" thick. With sheet metal, you must have non-
combustible material behind it. Noncombustible
material must extend at least 8" up (for all models).
If noncombustible material is less than 12", you
must install the replace hood accessory. Even if
noncombustible material is more than 12", you
may need the hood accessory to deect heat away
from your mantel shelf. See Figure 5 on page 9 and
Figures 6 and 7, for minimum clearances.
Figure 6 - Minimum Mantel Clearances
Without Using Hood
Minimum
Noncombustible
Material
Minimum
Noncombustible
Material Height
Distances to
Underside of
Mantel
Top of
Fireplace
Opening
Underside of
Mantel Shelf
Mantel Shelf
12"
(A)
18" 20" 22" 24"
All minimum
distances are
in inches
2
1
/2
"
6"
8"
10"
MANTEL CLEARANCES
In addition to meeting noncombustible material
clearances, you must also meet required clearances
between replace openings and mantel shelf on
each side of the replace. If you do not meet the
clearances listed below, you will need a hood.
If you meet minimum clearance between mantel
shelf and top of replace opening, a hood is not
required (see Figure 6).
If minimum clearances in Figure 6 are not met, you
must have a hood. When using a hood there are
still certain minimum mantel clearances required.
Follow minimum clearances shown in Figure 7
when using hood.
-
-
Follow all minimum clearances
NOTICE: If your installation does
not meet the minimum clear-
ances shown, you must do one
-
• remove the mantel
FLOOR CLEARANCES
A. If installing appliance on the oor level, you
must maintain the minimum distance of 14"
to combustibles (see Figure 8).
Figure 7 - Minimum Mantel Clearances
When Using Hood
Minimum
Noncombustible
Material
8"
Min.
12" 15" 18"
All minimum
distances
are in inches
20"
2
1
/2
"
6"
8"
10"
12"
Distances to
Underside of
Mantel
Hood
(GA6050,
GA6052 or
GA6053)
Top of
Fireplace
Opening
Underside
of Mantel
Shelf
Mantel Shelf
Figure 8 - Minimum Fireplace Clearances
If Installed at Floor Level
INSTALLATION
Continued