Desa CGEFP33PR Indoor Fireplace User Manual


 
108117-01J
For more information, visit www.desatech.com
For more information, visit www.desatech.com
27
27
CLEANING PILOT AIR INLET HOLE
Clean the pilot assembly also. A yellow tip on the pilot flame
indicates dust and dirt in the pilot assembly. There is a small pilot
air inlet hole about two inches from where the pilot flame comes out
of the pilot assembly (see Figure 58). With the unit off, lightly blow
air through the air inlet hole. You may blow through a drinking straw
if compressed air is not available. You may also clean the pilot air
inlet hole by pushing a common pipe cleaner completely through the
air inlet hole once.
LOGS
If you remove logs for cleaning, refer to Installing Logs, pages
21 and 22, to properly replace logs.
Replace log(s) if broken or chipped (dime-sized or larger).
Figure 58 - Pilot Inlet Air Hole (Natural Gas Model Shown)
Burner
Tube
Pilot
Assembly
Pilot Air
Inlet
Hole
Ports/Slots
CLEANING AND
MAINTENANCE
Continued
CLEANING AND MAINTENANCE
Cleaning Pilot Air Inlet Hole
Logs
SPECIFICATIONS
SERVICE HINTS
TECHNICAL SERVICE
SPECIFICATIONS
Btu (Variable) 20,000/33,000
Type Gas Natural: (CG)EFP33NR
Propane/LP: (CG)EFP33PR
Ignition Electronic (Automatic)/Piezo (Manual)
Natural Gas Propane/LP Gas
Manifold Pressure 3.5" W.C. 8.0" W.C.
Inlet Gas Pressure (in. of water)
Maximum 10.5" 14"
Minimum* 5" 11"
Shipping Weight 122 lbs. 122 lbs.
* For input adjustment
SERVICE HINTS
When Gas Pressure Is Too Low
pilot will not stay lit
burners will have delayed ignition
heater will not produce specified heat
for propane/LP units, propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, contact your local
natural or propane/LP gas supplier.
TECHNICAL SERVICE
You may have further questions about installation, operation, or
troubleshooting. If so, contact DESA Heating Products’ Technical
Service Department at 1-866-672-6040. When calling please have
your model and serial numbers of your heater ready.
You can also visit DESA Heating Products’ technical service web
site at www.desatech.com.