Desa CGEFP33PR Indoor Fireplace User Manual


 
108117-01J
For more information, visit www.desatech.com
For more information, visit www.desatech.com
24
OPERATING FIREPLACE
Normal Lighting Instructions
To Turn Off Gas To Appliance
NORMAL LIGHTING
INSTRUCTIONS
WARNING: You must operate this heater with the
fireplace screen in place. Make sure fireplace screen is
in place before running heater.
NOTICE: During initial operation of new heater, burning
logs will give off a paper-burning smell. Open damper or
window to vent smell. This will only last a few hours.
1. STOP! Read the safety information, page 23, column 2.
2. Make sure equipment shutoff valve is fully open.
3. Wait five (5) minutes to clear out any gas. Smell for gas
around heater and near floor. If you smell gas, STOP! Fol-
low “B” in the safety information on warnings plate. If you
don’t smell gas, go to the next step.
A. Using Supplied Wall Switch
1. Set manual ignition bypass switch on the control panel to
the OFF position (automatic ignition position).
2. Press ON/OFF button. Hold for 6 seconds. Gas valve will
open and electronic ignition will begin sparking to light
pilot. LED will light.
Note:
You may be running this heater
for the first time after connecting to gas supply or at the
start of your heating season. If so, the ON/OFF button may
need to be pressed again. This will allow air to bleed from
gas system. If several attempts to light pilot fail, contact a
qualified service person or gas supplier for repairs. Until
repairs are made, light and operate manually (see Manual
Lighting Instructions for Electric Power Outage, page 25).
3. When pilot flame is lit, the thermocouple is heated by the
flame. When thermocouple becomes hot (5 to 15 seconds),
main burner will automatically light on high flame.
4. To lower flame, push HI/LO button on wall switch once.
Note:
This fireplace does not have a pilot-only mode.
OPERATING FIREPLACE
Continued
ON
OFF
HI
LO
MANUAL
IGNITION
Figure 51 - Control Locations
Manual Ignition
Bypass Switch (Up is
for Remote Control)
ON/OFF Button
HI/LO
Button
Wall
Switch
LED
B. Using Hand-Held Wireless Remote Control
1. Set manual ignition bypass switch on control panel to OFF
position (automatic ignition position).
2. Wait five (5) minutes to clear out any gas. Smell for gas
around heater and near floor. If you smell gas, STOP! Fol-
low “B” in the safety information on warnings plate. If you
don’t smell gas, go to the next step.
3. Point remote control toward the lower front of fireplace
and push both buttons at the same time. Hold for 6 sec-
onds. The gas valve will open and electronic ignition will
begin sparking to light the pilot.
Note:
You will be able to
hear a clicking sound during this process. LED on wall
switch will light.
Note:
You may be running this heater for the first time
after connecting to gas supply or at the start of your heat-
ing season. If so, the ON button may need to be pressed
again. This will allow air to bleed from gas system. If sev-
eral attempts to light pilot fail, contact a qualified service
person or gas supplier for repairs. Until repairs are made,
light and operate manually (see Manual Lighting Instruc-
tions for Electrical Power Outage, page 25).
4. When pilot flame is lit, the thermocouple is heated by the
flame. When thermocouple becomes hot (5 to 15 seconds),
main burner will automatically light on high flame.
5. To lower flame, point remote control toward lower front of
fireplace and push HI/LO button once.
Note:
This fireplace does not have a pilot-only mode.
CAUTION: Do not try to adjust heating levels by
using the equipment shutoff valve.
Automatic
Ignitor
Electrode
Pilot
Burner
Figure 52 - Pilot (Natural Gas)
Manual Ignitor
Electrode
Figure 53 - Pilot (Propane/LP
Gas)
Automatic
Ignitor
Electrode
Pilot
Burner
Manual Ignitor
Electrode
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater - Wall Switch
Push ON/OFF button on wall switch once.
Shutting Off Heater - Wireless Remote Control
Point remote control toward lower front of fireplace and push
both buttons at the same time.