www.desatech.com
111160-01C 25
3. Blow air through the ports/slots and holes in
the burner.
4. Check the injector holder located at the end
of the burner tube again. Remove any large
particles of dust, dirt, lint, or pet hair with a
soft cloth or vacuum cleaner nozzle.
5. Blow air into the primary air holes on the in-
jector holder.
6. In case any large clumps of dust have now been
pushed into the burner repeat steps 3 and 4 on
page 24.
Clean the pilot assembly also. A yellow tip on the
pilot flame indicates dust and dirt in the pilot as-
sembly. There is a small pilot air inlet hole about
two inches from where the pilot flame comes out
of the pilot assembly (see Figure 42). With the
unit off, lightly blow air through the air inlet hole.
You may blow through a drinking straw if com-
pressed air is not available.
CLEANING AND
MAINTENANCE
Continued
Figure 41 - Injector Holder On Outlet
Burner Tube
Burner Tube
Primary Air
Inlet Holes
Injector
Holder
Figure 42 - Pilot Inlet Air Hole
Burner Tube
Pilot Assembly
Pilot Air
Inlet Hole
Ports/Slots
LOGS
• If you remove logs for cleaning, refer to In-
stalling Logs, pages 16 through 19, to properly
replace logs.
• Replace log(s) if broken or chipped (dime-sized
or larger).
MAIN BURNER
Periodically inspect all burner flame holes with
the heater running. All slotted burner flame holes
should be open with yellow flame present. All
round burner flame holes should be open with a
small blue flame present. Some burner flame holes
may become blocked by debris or rust, with no
flame present. If so, turn off heater and let cool.
Remove blockage. Blocked burner flame holes
will create soot.
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• for propane/LP units, propane/LP gas supply
may be low
You may feel your gas pressure is too low. If so,
contact your local propane/LP or natural gas sup-
plier.
TECHNICAL SERVICE
You may have further questions about installation,
operation, or troubleshooting. If so, contact DESA
Heating Products’ Technical Service Department
at 1-866-672-6040. When calling please have your
model and serial numbers of your heater ready.
You can also visit DESA Heating Products’ tech-
nical service web site at www.desatech.com.