Desa CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, CCL3930NT Water Heater User Manual


 
2
107123
VENT-FREE NATURAL GAS LOG HEATER
For more information, visit www.desatech.com
1. This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases.
2. If you smell gas
shut off gas supply
do not try to light any appliance
do not touch any electrical switch; do
not use any phone in your building
immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions
if you cannot reach your gas supplier,
call the fire department
3. This heater shall not be installed in a
bedroom or bathroom, unless installed
as a vented appliance (Variable Manu-
ally-Controlled Models Only). See In-
stalling Damper Clamp Accessory for
Vented Operation, page 10.
SAFETY
INFORMATION
IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble, oper-
ate, or service this heater. Im-
proper use of this heater can cause
serious injury or death from burns,
fire, explosion, electrical shock,
and carbon monoxide poisoning.
Carbon Monoxide Poisoning: Early signs
of carbon monoxide poisoning resemble the
flu, with headaches, dizziness, or nausea. If
you have these signs, the heater may not be
working properly. Get fresh air at once!
Have heater serviced. Some people are more
affected by carbon monoxide than others.
These include pregnant women, people with
heart or lung disease or anemia, those under
the influence of alcohol, and those at high
altitudes.
Natural Gas: Natural gas is odorless. An
odor-making agent is added to the gas. The
odor helps you detect a gas leak. However,
the odor added to the gas can fade. Gas may
be present even though no odor exists.
Make certain you read and understand all
warnings. Keep this manual for reference. It
is your guide to safe and proper operation of
this heater.
WARNINGS
WARNING: Any change to
this heater or its controls can be
dangerous.
4. Before installing in a solid fuel burn-
ing fireplace, the chimney flue and fire-
box must be cleaned of soot, creosote,
ashes, and loose paint by a qualified
chimney cleaner. Creosote will ignite
if highly heated. Inspect chimney flue
for damage. If damaged, operate heater
with flue damper closed.
5. If fireplace has glass doors, never op-
erate this heater with glass doors closed.
If you operate heater with doors closed,
heat buildup inside fireplace will cause
glass to burst. Also if fireplace open-
ing has vents at the bottom, you must
open the vents before operating heater.
6. This log heater is designed to be smoke-
less. If logs ever appear to smoke, turn off
heater and call a qualified service person.
Note:
During initial operation, slight
smoking could occur due to log curing and
heater burning manufacturing residues.
7. To prevent the creation of soot, follow
the instructions in Cleaning and Main-
tenance, page 21.
8. Before using furniture polish, wax, car-
pet cleaner, or similar products, turn
heater off. If heated, the vapors from
these products may create a white pow-
der residue within burner box or on
adjacent walls or furniture.
9. This heater needs fresh, outside air ven-
tilation to run properly. This heater has
an Oxygen Depletion Sensing (ODS)
safety shutoff system. The ODS shuts
down the heater if not enough fresh air
is available. See Air for Combustion
and Ventilation, pages 4 through 6. If
heater keeps shutting off, see Trouble-
shooting, pages 22 through 24.
10. Do not run heater
where flammable liquids or vapors
are used or stored
under dusty conditions
11. Do not use this heater to cook food or
burn paper or other objects.
12. Do not use heater if any part has been
exposed to or under water. Immediately
call a qualified service technician to in-
spect the room heater and to replace any
part of the control system and any gas
control which has been under water.
13. Do not operate heater if any log is bro-
ken. Do not operate heater if a log is
chipped (dime-sized or larger).
WARNING: Do not allow fans
to blow directly into the fireplace.
Avoid any drafts that alter burner
flame patterns. Ceiling fans can
create drafts that alter burner
flame patterns. Altered burner
patterns can cause sooting.
DANGER: Carbon monoxide
poisoning may lead to death!
WARNING: Do not use a
blower insert, heat exchanger
insert or other accessory not ap-
proved for use with this heater.
Due to high temperatures, the
appliance should be located out
of traffic and away from furniture
and draperies.
Do not place clothing or other
flammable material on or near
the appliance. Never place any
objects on the heater.
Heater base assembly becomes
very hot when running heater.
Keep children and adults away
from hot surface to avoid burns
or clothing ignition. Heater will
remain hot for a time after shut-
down. Allow surface to cool be-
fore touching.
Carefully supervise young chil-
dren when they are in the room
with heater.
You must operate this heater with
a fireplace screen in place. Make
sure fireplace screen is closed
before running heater.
Keep the appliance area clear and
free from combustible materials,
gasoline, and other flammable
vapors and liquids.