Desa C42EC2 Indoor Fireplace User Manual


 
2
55951
45
1
/4"
43
1
/2"
11
3
/16"
23
5
/8"
Figure 1 - Framing Dimensions
INSTALLATION
INSTRUCTIONS
INTRODUCTION
Before beginning the installation of your firebox, read these instruc-
tions through, completely.
These Comfort Glow components and fireboxes are safe when
installed according to this Installation Manual. Unless you use
Comfort Glow components which have been designed and tested for
the firebox system, you may cause a fire hazard.
The DESA International warranty will be voided by, and DESA
International disclaims any responsibility for the following actions:
a) Modification of the firebox, components, doors, blower fans,
air inlet system and damper control.
b) Use of any component part not manufactured or approved by
DESA International, in writing, in combination with a DESA
International firebox system.
Refer to your Homeowners guide for warranty information.
HEIGHT: The minimum height of the chimney, measured from the
base of the firebox to the flue gas outlet, is 16 feet for a straight
chimney or with one elbow set. For systems with 2 elbow sets, the
minimum height is 30 feet. The maximum height of any system is 60
feet. This measurement includes the firebox, chimney sections and
the effective height of the termination assembly.
GENERAL
Read the Warranty and Operating guidelines supplied with this
firebox. Following these simple guidelines will ensure years of
trouble free and safe usage of your firebox. If the Warranty and
Operating instructions are not in your firebox, write to the address
listed on the front cover.
INSTALLING THE FIREBOX
STEP 1: Frame the opening for the firebox using the dimensions
shown in Figure 1 or Figure 2.
STEP 2: Set the firebox directly in front of this opening and slide the
unit back until the mounting flanges touch the side framing.
STEP 3: Check the level of the firebox and shim with sheet metal if
necessary.
STEP 4: When the firebox is installed upon a combustible floor a
galvanized steel ember protector (provided) must be installed be-
tween the firebox and the hearth extension as illustrated in Figures
12 and 13.
STEP 5: Secure the firebox to the framing through the flanges
located on the sides on the firebox with nails, or screws.
Note:
The 3/4" clearance is not required at the nailing flange. (see
Figure 10)
WARNING: Never use gasoline, gasoline-type lantern
fuel, kerosene, charcoal lighter fluid, or similar liq-
uids to start or “freshen up” a fire in this firebox. Keep
all such liquids well away from the firebox.
WARNING: Do not pack required air spaces with
insulation or other material.
WARNING: Do not install a fireplace insert in this
firebox unless the manufacturer’s instructions with
the insert specifically state this firebox has been
tested for use with the insert.
PROPER INSTALLATION is the most important step in ensuring
safe and continuous operation of this firebox. Consult the local
building codes as to particular requirements concerned with the
installation of all factory built fireboxes. Although grounding may
not be required by code it is recommended by the manufacturer.
FOR YOUR SAFETY
Do not store or use gasoline or any other flam-
mable vapors or liguids in the vicinity of this or
any other appliance.
Due to high temperatures, the appliance should
be located out of traffic and away from furniture
and draperies.
Do not place clothing or other flammable mate-
rials on or near the appliance.
NEVER leave children unattended when a fire is
burning in the fireplace.
WARNING: Improper installation, adjustment, alter-
ation, service, or maintenance can cause injury, prop-
erty damage, or loss of life. Refer to this manual. For
assistance or additional information consult a quali-
fied installer or local distributor.
WARNING: This fireplace is intended for use with
wood, decorative gas appliance, and vent-free gas
logs which burn propane/LP or natural gas only.
CHECK LOCAL CODES PRIOR TO INSTALLATION
This wood burning fireplace complies with UL127 as a Factory-
Built Fireplace and is listed and tested by Underwriters Labo-
ratory, Inc.
This model is not for use in mobile homes.
MINIMUM CLEARANCES TO COMBUSTIBLES
Framing and enclosures may safely make direct contact with the
spacers on the top of the firebox. The firebox may sit directly on
combustible flooring (see Step 4, below). The firebox opening must
not be less than 24 inches from combustible materials and the chimney
must be absolutely maintained. A 16
1
/2 inch inside chase dimension
is recommended as a minimum size. A 3/4 inch air space is required
around back and sides of firebox.
Keep all combustible furnishings a considerable distance from the
firebox.
This firebox is not intended to be used as a substitute for a
furnace to heat an entire home. Use for supplementary
heating only.