Desa 30" Water Heater User Manual


 
110882-01C
For more information, visit www.desatech.com
For more information, visit www.desatech.com
22
FRONT BURNER FLAME PATTERN
Figure 36 shows correct front burner flame pattern. Figure 37 shows
incorrect front burner flame pattern. The incorrect burner flame
pattern shows yellow tipping at top of blue flame.
WARNING: If yellow tipping occurs, your heater
could produce increased levels of carbon monoxide.
If front burner flame pattern shows yellow tipping,
follow instructions at bottom of this page. Yellow
flame on rear burner is normal.
NOTICE: Do not mistake orange flames with yellow
tipping. Dirt or other fine particles are burned by
heater, causing brief patches of orange flame.
If front burner flame pattern is incorrect, as shown in Figure 37
turn heater off (see To Turn Off Gas to Appliance, page 17 [Ther-
mostat-Controlled Models], page 18 [Manually-Controlled
Models], or page 20 [Remote-Ready Models])
see Troubleshooting, pages 24 through 26
INSPECTING BURNERS
Check pilot flame pattern and burner flame patterns often.
PILOT FLAME PATTERN
Figure 34 shows a correct pilot flame pattern. Figure 35 shows an
incorrect pilot flame pattern. The incorrect pilot flame is not
touching the thermocouple. This will cause the thermocouple to
cool. When the thermocouple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown in Figure 35
turn heater off (see To Turn Off Gas to Appliance, page 17 [Ther-
mostat-Controlled Models], page 18 [Manually-Controlled
Models], or page 20 [Remote-Ready Models])
see Troubleshooting, pages 24 through 26
Note:
The pilot flame on natural gas units will have a slight curve,
but flame should be blue and have no yellow or orange color.
Figure 34 - Correct Pilot Flame Pattern (Your pilot may vary from
pilots shown)
Figure 36 - Correct Front Burner Flame Pattern
Figure 37 - Incorrect Front Burner Flame Pattern
Yellow Tipping At Top
of Blue Flame
INSPECTING BURNERS
Pilot Flame Pattern
Front Burner Flame Pattern
Pilot Burner
Thermocouple
Figure 35 - Incorrect Pilot Flame Pattern (Your pilot may vary
from pilots shown)
Pilot Burner
Thermocouple
Thermocouple
Pilot Burner
Thermocouple
Pilot Burner