USING THE QUICK COUPLINGS
As an alternative to the methods described
above, the sheath connecting the external
and internal units can be passed through a 6
cm diameter hole in an perimeter wall.
In this case, the external unit couplings must
be disconnected as follows:
1) Unplug the appliance from the mains sup-
ply.
2) Remove the handle by removing the screw
covers and unscrewing the two fixing pins
and the two metric screws; then remove
the front panel.
Setting up (Mod. FX400ECO)
NB: Leave at least 30 cm between the wall
and the appliance.
b) Through a small hole made in the bottom
of a door or the frame of a window, using
the sheath frame (22) supplied (fig 8).
PREPARING THE INTERNAL UNIT (1)
Install the appliance inside the room to be air
conditioned, usually near a window or a peri-
meter wall.
The internal unit must be positioned level. Use
the wheel blocks (20) supplied. The intake
zone (intake grill (8)) and the discharge zone
(discharge grill (2)) must be kept clear of
obstacles.
POSITIONING THE CONNECTING SHEATH
The sheath connecting the external and inter-
nal units can be passed:
a) Through the gap in a window or door left
ajar; use the suckers (20) to prevent ope-
ning further (fig. 7).
SHEATH CLIP
ELECTRICAL
CONNECTION
BLOCK
PROTECTION
“U”-STAY
3) Remove the “U” stay by unscrewing the
two metric screws (fig 9).
4) Remove the sheath clip (fig 9).
5) Using a 24 mm spanner, undo the rotating
connection on the coupling. At the same
time, using a 21 mm spanner, hold the end
of the flexible tube (fig10). (repeat for the
second connection using a 24 mm and a
19 mm spanner)
6) Disconnect the condensate tube from the
pipe fitting.
cm 30
cm 30
cm 30
7
8
9
10