Defy Appliances Part Number 059 044 Air Conditioner User Manual


 
Silhouette Console Installation instructions
PRIOR TO INSTALLATION
Remove the filter assembly.
Loosen the two screws at the bottom corners of the access cover and remove it.
Loosen the two screws at either end of the fan deck.
Disconnect the multi-plug and slide the fan deck out.
Protect the deck against dust generated during the installation process.
Secure the unit to the wall using at least four of the fixing holes provided. ( See sketch above )
Ensure that the unit is properly and accurately fitted to the wall sleeve assembly.
Should the factory fitted condenser coil foam seals not butt up to the louver assembly, insulated divider
plates must be fitted to prevent hot air re-circulation back into the condenser section.
It is also advisable to remove the side deflectors from the condenser coil and fit them directly behind the
louvre.
ELECTRICAL CONNECTION
Ensure that the supply voltage is 230V 50 Hz
This unit must be earthed and installed in accordance with local municipal safety standards.
If necessary, ensure that a qualified electrician replaces the mains cable.
CONSOLE UNIT
WALL SLEEVE
WALL APERTURE
100
550
390
400
405
310
335
900
220
720
735
745
100mm.
ABOVE FINISHED
FLOOR LEVEL
(INDOOR)
MOUNTING HOLES
MOUNTING HOLES