DCS -DRH48N Electric Heater User Manual


 
Lighting Instructions
11
Operation Instructions
Upon installation of the heater and completion of the gas line and electrical supply
to each heater, follow the steps outlined in the
lighting instructions. Lighting instruc-
tions
are also provide on the control panel.
Turn gas and power to
ON. The igniter should light within the first 4 seconds. If
not, the electrode sensor will shut-off the hot surface igniter. The igniter will attempt to
light 3 times before
locking out. During initial installation, this will happen if the gas line
is not purged. To reset the control, shut off the power to the unit and wait 5 seconds. Turn
power back to
ONposition. This will allow for 3 more lighting attempts.
To Start Heater
1). Turn manual gas valve to ON position.
2). Turn electrical supply
ON.
To Shut Down Heater
1). Turn electrical supply OFF.
2). Turn manual gas valve to OFF position.
CAUTION
: If burner fails to ignite, shut down electrical power and wait 5 minutes
before turning power
ON. To allow any gas to dissipate.