MOBILE HOME INSTALLATION
CAUTION: DO NOT INSTALL STOVE IN SLEEPING ROOM
THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR,
CEILING/ROOF MUST BE MAINTAINED!
Your PELPRO stove has been tested and listed for mobile home installation. It may be installed in a mobile
home as a "Free Standing Stove", a "Hearth Stove", or as an "In Insert" installed in an existing wood or coal-
burning fireplace or as an "Built –In Insert" installed with a mantel.
In addition to all previously detailed installation requirements, mobile home installations
must meet the following requirements:
Permanently bolt your stove to the floor, (A). Figure 23, 24
Electrically ground your stove or the pedestal to the steel frame of the home. Use a number 8 gauge copper
wire, (B) figure 24, or equivalent.
The stove must have a permanent outside air source with a ¼ inch screen over the inlet.
Figure 23, (B,C, D)
For transportation all chimney / vent above the mobile home must be removed.
“PL” Vent must be 3” or 4” PL Vent and must extend a minimum or 36” above the roofline of the
mobile home and must be installed using a UL/ULC listed ceiling fire stop (J), figure 23, and
rain cap (L), figure 23.
INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.
A
Floor Pad
B
Combustion Air Intake
C
Fresh Air Duct
D
Fresh Air Hood
E
Stove Exhaust
F
Pipe Adapter
G
Clean Out Tee
H
Tee Support Bracket
I
Pipe
J
Firestop Spacer / Ceiling Support
K
Roof Flashing / Storm Collar
L
Rain Cap
Figure 23 Figure 24
Note: When moving your Mobile Home, all exterior venting must be removed while Mobile Home is
being relocated. Upon completion of relocation all venting must be reinstalled and securely fastened.
B
A
C
D
G
H
I
J
K
L
FRAME
HEARTH PAD
FLOOR
B
GROUND
WIRE
A
BOLT(S)