Cumberland Stove Works MF3700 Stove User Manual


 
INSTALLATION AND OPERATION MANUAL
MF3700, MF3800 Models
Page 17800-345-6007
CumberlandStoveWorks.com
lighter, close the door and press ON key. The sound
youhearaftertheONkeyispushedistheexhaustfan
running. After the ON key is pressed the control will read
as follows:
STARTING FIRE
LEVEL 1
ELECTRIC IGNITION INSTRUCTIONS
(MF3800 only)
After the Range has been loaded the controller will then
read as follows
ELECTRIC IGNITE
NO
YES
IMPORTANT:Beforelightingthestoveforthersttime,
make sure that no shipping items have been left inside the
reboxorashpan.
Wheninitiallyllinganemptyhopperyoumustprimethe
feed auger. To prime the auger press the ADD FUEL button.
This will turn the auger on for one minute or until the ADD
FUEL button is pressed again. Run the feed auger until
youseefuelstarttodropintotherepot.
Note: The parlor stove has been designed with a safety
switch on the hopper lid. The auger will not run with the
hopper door open.
Once the auger is primed pressing ENTER will start the
electronicignitionsequence.Note:Preloadingtherepot
isn’t necessary for electric ignition; the program is designed
toautomaticallyloadtherepot.Thenoisesyouwillhear
during electric ignition are the combustion fan and air pump
running.Thescreenwillreadasfollows:
ELECTRIC IGNITE
LEVEL 1
STARTING FIRE AND ELECTRIC IGNITE
SCREENS
(MF3800 only)
The starting re and electric ignition sequences have
been designed to take a cold stove up to normal operating
temperature. These are preset feed rates and fans speeds
set by CSW to ensure the ignition of multiple types of
fuels.
During starting re andelectric ignition sequences you
may change the level by pressing the TEMP UP or TEMP
DOWN buttons.
Duringstartingreandelectricignitionsequencesyoumay
choose to run your stove thermostatically by pressing the
THERMOSTAT ON/OFF button. See Thermostatic Control
Operation.
Atanytimeyoumayaddmorefueltotherepotbypressing
theADDFUELbutton.Note:thefeedaugerwillstayon
for one minute or until the ADD FUEL button is pressed
again.
During starting re and electric ignition sequences the
convectionfan(thefanthatcirculateswarmairthroughout
room)willstartoncestovehasreached110degrees.To
control convection fan speed use Fan Up and Fan Down
buttons(Buttons3and8inFigure22).Note:Hotstoves
need air circulating through them at all times to prevent
overheating the electronic controls. Therefore, once proof
ofreismadetheconvectionfanwillcontinuetorun.
After the stove runs it’s startingre or electric ignition
sequences the controller will read RANGE 1-4(willdisplay
chosenfuelrange)LEVEL 1-6(willdisplaychosenheat
outputlevel).Thisisthenormaloperatingscreensforthe
MF series parlor stove.
NORMAL OPERATION
During normal manual operation of the stove the controller
will read asfollows:
TEMP 72
RANGE1-4LEVEL1-6
At any time during normal operation you will be able to
change the Fuel Range by pressing the SCROLL button.
(MF 3800 only)Atanytimeduringnormaloperationyouwill
be able to run the igniter by pressing the SCROLL button
during the normal operating
At anytime during normal operation you may change the
heat level by pressing the TEMP UP or TEMP DOWN
buttons.Note:ifthestoveisbeingcontrolledbythelocal
thermostat the TEMP UP and TEMP DOWN buttons control
the thermostat setpoint. If the stove is being controlled
by the remote thermostat the TEMP UP or TEMP DOWN
buttons have no effect on the heat output.
At anytime during normal operation you may turn on or off
the thermostatic control by pressing the THERMOSTAT
ON/OFF button.