Page 16 800-345-6007
CumberlandStoveWorks.com
OPERATING STOVE
Once the stove has been properly installed and plugged
into a grounded surge protector you are ready to begin
operation.
IMPORTANT: Before lling the hopper make sure all
shipping and packaging items are removed from the
hopper and there are no obstructions in the auger housing
opening.
Fill the hopper with an approved solid fuel and close the
lid.
Therstscreenyouwillseeuponpowerupisthemodel
and version of software loaded in the control. It will then
default to the Fuel Range Selection Mode.
FUEL RANGE SELECTION
The CSW Multi Fuel Parlor stove has four fuel ranges
andsixheatoutputLevels withineachfuelrange.This
gives thestove24 levels of variability maximizing burn
with your chosen fuel. Range 1 Level 1 is the lowest feed
rate/combustionairowandRange4Level6isthehighest
feedrate/combustionairow.Seegure23.
RANGES FOR APPROVED FUELS
•Corn1-2
•WoodPellets2-3-4
• Cherry Pits 4
SELECTING THE RANGE
The control will offer two selections on the screen. To
browse through the range selections use the SCROLL
button. To choose a range scroll through until the desired
Range is on top and press ENTER. Range may be changed
at anytime during stove operation by pressing the SCROLL
button.
STARTING A FIRE
After the Range has been loaded the controller will then
instructyoutolightthere.MF3700stovecontrollerswill
readasfollows:
LIGHT FIRE
PUSH ON BUTTON
Stovesequippedwithelectricignition(modelMF3800)will
havetheoptionofstartingtheremanuallyorautomatically
withtheigniter.Thescreenwillreadasfollows:
ELECTRIC IGNITE
NO
YES
Pushing SCROLL will send the controller to the LIGHT
FIRE PUSH ON BUTTON. See Manual Lighting Instructions
beforestartingreorpushingON.Forelectricignitionread
ELECRTRIC IGNITION INSTRUCTIONS before pressing
ENTER.
MANUAL LIGHTING INSTRUCTIONS
IMPORTANT:Beforelightingthestoveforthersttime,
make sure that no shipping items have been left inside the
reboxorashpan.
Wheninitiallyllinganemptyhopperyoumustprimethe
feed auger. To prime the auger press the ADD FUEL button.
This will turn on your auger on for one minute or until the
ADD FUEL button is pressed again. Run feed auger until
youseefuelstarttodropintotherepot.
Note: The parlor stove has been designed with a safety
switch on the hopper lid. The auger will not run with the
hopper door open.
Fill the repot with about one cupofstarting pellets or
wood pellets. If wood pellets are used, squirt about two
tablespoons of burn gel on pellets.
Lightthematerialinrepotusingamatchoragrilltype
WARNING
NEVER PUT STARTING PELLETS OR BURN GEL INTO
THE HOPPER OF THE STOVE. THIS COULD RESULT
IN DEATH OR SERIOUS INJURY AND OR PROPERTY
DAMAGE. DOING SO WILL VOID ALL WARRANTIES.
Range 4
Range 3
Range 2
Range 1
Lowest Feed Rate/
Combustion Airflow
Highest Feed Rate/
Combustion Airflow
Levels 1-6
Levels 1-6
Levels 1-6
Levels 1-6
Figure23:Feedratechart.