Cumberland Stove Works MF3700 Stove User Manual


 
INSTALLATION AND OPERATION MANUAL
MF3700, MF3800 Models
Page 14 800-345-6007
CumberlandStoveWorks.com
VENT TERMINATION CLEARANCES
CLEARANCE
4 feet
Clearance below or beside any door or window
that opens.
1 foot
Clearance above any door or window that
opens.
3 feet Clearance from any adjacent building.
7 feet
Clearance from any grade when adjacent to
public walkways.
2 feet
Clearance above any grass, plants, or other
combustible materials.
3 feet
Clearance from any forced air intake of any
appliance.
2 feet Clearance below eaves or overhang.
1 foot
Clearance horizontally from combustible
wall.
3 feet Clearance above the roof.
2 feet
Clearance above the highest point on the roof
within 10 feet.
VENTING INSTALLATION EXAMPLES
Figure 20: STRAIGHT INSTALLATION
Inside Vertical Rise, Horizontal Termination
Figure 19: STRAIGHT INSTALLATION
Outside Vertical Rise, Through Wall Installation
INSTALLING REMOTE THERMOSTAT
The MF Parlor Stove can be run thermostatically by
purchasinganymilivoltthermostat(soldseparately).This
step is optional and not required for MF Parlor Stove to
operate.
Mountthermostataccordingtomanufacturerspecications.
Using a small flat head screw driver, tighten remote
thermostatwiresintopins7and8.Seegure18.
remote
thermostat
terminals
Figure18:RemoteThermostatTerminals