UNVENTED (VENT-FREE) FIREBOX
INSTALLATION
Continued
INSTALLING BLOWER
ACCESSORY (MODEL
CGFB32C ONLY)
You may install blower accessory GA3750
with conventional installation (below) or with
built-in installation (page 10) with model
CGFB32C only. To install blower accessory,
see instruction sheet included with the kit.
Conventional Installation of
Blower Accessory
1. Install blower assembly per instruction
sheet included in blower accessory kit.
2. Before replacing bottom of firebox,
route blower power cord through hole
in support bracket in bottom of firebox
and through hole in side of firebox to
grounded, three-prong 120 volt electri-
cal outlet (see Figure 8). Plug electri-
cal cord into outlet.
3. Replace bottom of firebox.
NOTICE: A certified electrician
must connect electrical wiring to
duplex outlet for built-in installa-
tion. Follow all local codes. In
absence of local codes, follow
the National Electrical Code, ANS/
NFPA 70 (Latest Edition).
Electrical
Outlet
Side
Opening
Support Bracket
Opening
Slower Power
Cord
Figure 8 - Routing Blower Accessory
Power Cord for Conventional Installation
Built-In Installation of Blower
Accessory
1. Install blower assembly per instruction
sheet included.
2. Before replacing bottom of firebox,
remove screw holding duplex outlet to
the support bracket in the bottom of
firebox, Remove duplex outlet.
3. Clamp electrical cable into firebox
through smallest hole using strain re-
lief provided.
4. Route wires from electrical box through
hole in side of heater and hole in sup-
port bracket (see Figure 9).
5. Connect wires from the electrical box
to duplex outlet. Match wire colors to
those indicated on duplex outlet. Be
sure to connect ground wire.
6. Replace duplex outlet with screw.
7. Plug blower power cord into duplex
outlet.
8. Replace bottom of firebox.
Cables From
Electrical
Source
Duplex
Outlet
Screw
SlowerPower
Cord
Figure 9 - Routing Blower Accessory
Power Cord for Built-In Installation
INSTALLING LOG HEATER IN
FIREBOX
_]k CAUTION: Do not pick up log
base assembly by burners, This
could damage burners. Only
handle base by grates.
_k CAUTION: Do not remove the
metal data plates attached to the
heater base assembly. The data
plates contain Important warranty
Information.
1. Remove four screws holding firebox
bottom in place.
2. Lift and remove firebox bottom (see
Figure 10).
3. If installing GA3750 Blower Accessory
(Model CGFB32C only), see Install-
ing Blower Accessory.
4. Route flexible gas line from manual
shutoff valve into firebox through side.
NOTICE: Most building cedes do
not permit concealed gas con-
nections. A flexible gas line is
recommended to allow accessi-
bility from the firebox. The flex-
ible gas supply line connection
to the manual shutoff valve
should be accessible,
5. Attach gas log heater base to firebox
bottom with four screws included with
base (see lnstallihg Heater Base As-
sembly in log set owner's manual).
6. Replace firebox bottom and secure with
screws.
B
Figure 10- Removing Firebox Bottom
8 1o3573