Desa Tech CGD3930PT Indoor Fireplace User Manual


 
AIR FOR
COMBUSTION
AND
VENTILATION
Continued
WARNING
If the area in which the heater may be operated is smaller than
that defined as an unconfined space, provide adequate combus-
tion and ventilation air by one of the methods described in the
National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.3 or appli-
cable local codes.
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining unconfined space. When ventilating to an
adjoining unconfined space, you must provide two permanent openings: one within 12" of the
ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1
and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2).
Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion
2nd Ventilation for required size of ventilation grills or ducts.
WARNING
Rework worksheet, adding the space of the adjoining unconfined
space. The combined spaces must have enough fresh air to supply all
appliances in both spaces.
Ven--
Grills Ventila_on Gdlls
Into Adjoining O_ Into Adjoining Room.
Room, Remove II Op_on 2
Op_on 1 Door into li
Adjoiningil
Room,
OptionOll
Figure 2 - Ventilation Air from Inside Building
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must provide two perma-
nent openings: one within 12"of the ceiling and one within 12" of the floor. Connect
these items directly to the outdoors or spaces open to the outdoors. These spaces include
attics and crawl spaces.
IMPORTANT: Do not provide openings for inlet oroutlet airinto attic if attic has a thermostat-
controlled power vent. Heated air entering the attic will activate the power vent.
Outer
/_ir
I
TO Attic
========== To
c"
spa=
I
Inka/U¢ I Verl_llted
Cr,_s_= I
'ure 3 - Ventilation Air from Outdoors
n IF4