18" Model 24" Models 30" Models
Btu (Variable) 16,000/30,000 20,000/39,000 20,000/39,000
Type Gas Propane Only Propane Only Propane Only
Ignition Piezo Piezo Piezo
Manifold Pressure 8.0" W.C. 8.0" W.C. 8.0" W.C.
Inlet Gas
Pressure (in. of water)
Maximum 14" 14" 14"
Minimum* 11" 11" t 1"
Shipping Weight 28 Ibs.
* For the purpose of input adjustment
30 lbs. 32 lbs.
When gas pressure is too low
pilot will not stay lit
burners will have delayed ignition
heater will not produce specified heat
propane gas supply may be low
When gas quality is bad
pilot will not stay lit
burners will produce flames and soot
heater will backfire when lit
You may feel your gas pressure is too low or gas quality is bad. If so, contact your
local propane gas supplier.