Desa Tech CGD3930PT Indoor Fireplace User Manual


 
INSTALLING
Con_nued.
3. Pressurize supply piping system by either using compressed air of
opening propane supply tank valve.
4. Check all joints of gas supply piping system. Apply mixture of liquid soap and
water to gas joints• Bubbles forming show a leak.
5. Correct all leaks at once.
6. Reconnect heater and manual shutoff valve to gas supply. Check reconnected
fittings for leaks.
Test Pressures Equal To or Less Than 1/2 PSIG
1. Close manual shutoff valve (seeFigure 15).
2. Pressurize supply piping system by either using compressed air or opening
propane supply tank valve.
3. Check all joints from propane supply tank to manual shutoff valve (see Figure
16). Apply mixture of liquid soap and water to gas joints. Bubbles forming
show a leak.
4. Correct all leaks at once.
Pressure Testing Heater Gas Connections
1. Open manual shutoff valve (see Figure 15).
2. Open propane supply tank valve.
3. Make sure control knob of heater is in the OFF position.
4. Check all joints from manual shutoff valve to control valve (see Figure 16).
Apply mixture of liquid soap and water to gas joints. Bubbles forming show a
leak.
5. Correct all leaks at once.
6. Light heater (see Operating Heater, pages 20 through 22 [manually-controlled
models] or pages 22 through 24 [thermostatically-controlled models]). Check
all other internal joints for leaks.
7. Turn offheater (see To Turn OffGas to Appliance, page 21 [manually-con-
trolled models] or page 24 [thermostatically-controlled models]).
Shutoff
Valve
sed
Figure
Propane
Supply Ta__. __
_ ,L_, ,ff*_.._.... -,-_,..._.._,
15 - Manual Shutoff Valve
Manual
• "_ Shutoff
,//
.... Valve
,,_
///,
"/ /
//
:_._ --
To;..-=
Thermostat Gas Valve or
Control Valve Location
/
i i i , i i i i _ i _ i
Figure 16. Checking Gas Joints