Clarke L17 Vacuum Cleaner User Manual


 
Page -24- Clarke
®
Operator's Manual -FOCUS S17/L17 and S20/L20
EN
Maintenance
REAR BLADE
0.06 (1.5 mm)
Figure 37
Figure 38
Figure 39
Maintenance For The Squeegee
To remove the squeegee, follow this procedure:
1. Remove the squeegee assembly by loosening the two
knobs that attach the squeegee to the machine. Pull
the squeegee assembly off (See figure 37).
2. Inspect the squeegee blade.
3. If the blade is worn, turn the blade so that a new edge
is in the wiping position.
4. Reinstall squeegee assembly on the machine.
How To Adjust The Squeegee
The following adjustments are set at the factory, however
they may require slight adjustment.
Adjusting Squeegee Tilt:
The tilt of the squeegee causes the rear blade to raise up
in the center or on the ends, depending on which
direction the tilt is changed. For tilt adjustment, refer to
figure 38. Loosen left and right screw "X". In order to
bring the blades down in the center, tip "Y" down. To
bring both ends down, tip "Y" up. Make very small
adjustments and try it until a uniform flare is achieved.
Adjusting Squeegee Blades:
When properly installed the front blade should be ap-
proximately 0.06" (1.5mm) above the rear blade (See
figure 39).
WARNING: Maintenance and repairs must be
done by authorized personnel
only .
WARNING: Electrical repairs must be done by
authorized personnel only.
Consult your Clarke Authorized Service Person to do
the service procedures.
Use only genuine Clarke parts.