12
Stardance Direct Vent/Natural Vent Gas Heater
20007065
Venting Requirements and Options -
Direct Vent ONLY
Approved Vent System Components
The Stardance Heater must be vented to the outdoors
through an adjacent exterior wall or through the roof.
The venting system must be comprised of the appropri-
ate listed venting components specified on this page.
These parts are available from DuraVent Corporation or
your Vermont Castings Dealer.
See Figure 4 for dimensions relevant to the standard
minimum-vent kits.
Simpson DuraVent Components
Minimum Horizontal Vent Kit 2792
Starter Pipe Assembly
(incl. inner & outer sections) 2768*
90° Elbow, Blk. 990B*
45° Elbow, Gal. 945
6” Straight, Blk. 908B*
9” Straight, Blk. 907B
11” - 14B\,” Adjustable Straight Section 911B
12” Straight 906
24” Straight 904B*
36” Straight 903B
48” Straight 902
Horizontal Vent Cap 984*
Wall Plate 940*
Vinyl Siding Shield 950
Snorkel Termination - 14” 982
Snorkel Termination - 36” 981
Wall Strap 988
Cathedral Ceiling Support Box 941
Storm Collar 953
Firestop Spacer 963
Flashing 0/12 - 6/12 943
Flashing 6/12 - 12/12 943S
Steel Chimney
Kit A 931
Kit B 932
Kit C 933
Masonry Chimney Kit 934
Vertical Termination Cap (High Wind) 991
Vertical Termination Cap (Low Profile) 980
*Included in Minimum Horizontal Vent Kit #2792
All DuraVent Straight vent pipe sections have a net
length 1¹⁄₂” (37mm) less than the nominal dimension;
i.e., a 6” (152mm) Straight pipe section has an effective
length of 4¹⁄₂” (115mm).
CFM Vent Components
The following kits are available to meet the needs of
most installations. All pipe has a 7” outer diameter and
includes a 4” diameter inner section. A (CG) designa-
tion indicates the part is finished in Charcoal Gray paint.
Consult your dealer about other vent parts that may be
appropriate to complete the installation.
Min. Through the Wall Vent Kit 7TFSSK
(1) 90-Degree Elbow (CG)
(1) 24” Straight pipe (CG)
(1) 24” - 42” Adjustable Straight Pipe
(1) Side Wall Termination
(1) Firestop
(1) Zero-clearance sleeve
(1) Hardware package
(1) Finishing plate (CG)
(1) Finishing collar (CG)
(4) Charcoal Gray flue pipe rings
Starter Kit for Below Grade Installation 7TDVSKS
(1) Snorkel Termination (7TDVSNORK)
Vertical Termination Kit, 1/12-6/12 Pitch 7TDVSKVA
(1) Combination Horizontal Offset / Roof Support
(1) Vertical Termination
(1) Storm Collar
(1) 1/12-6/12 Flashing
(1) Finishing Plate (CG)
(1) Finishing Collar (CG)
(1) Polished Brass Flue Pipe Ring
(1) Hardware Package
Vertical Termination Kit, 7/12-12/12 Pitch 7TDVSKVB
(1) 7/12 - 12/12 Flashing
and all of the other Vertical Termination parts.
Vertical Termination, Flat Roof 7DVSKVF
(1) Flat Flashing
and all of the other Vertical Termination parts.
Twist Lock 12” Straight Pipe (CG) 7TFSDVP12
(1) 12” Non-adjustable Pipe
Twist Lock 12”-18” Straight Pipe (CG) 7TFSDVP1218
(1) 12” - 18” Adjustable Pipe
Twist Lock 24” Straight Pipe (CG) 7TFSDVP24
(1) 24” Non-adjustable Pipe
Twist Lock 48” Straight Pipe (CG) 7TFSDVP48
(1) 48” Nonadjustable Pipe
Twist Lock 45-Degree Elbow (CG) 7TFSDVT45
for vertical offsets
(1) 45-degree Elbow
Draft Hood Adapter FSDHAG
NV Stove Kit 7FSSK
(1) 7” Diameter Polished Brass Trim Ring
(1) 48” Nonadjustable Pipe (CG)
(1) 24” Nonadjustable Pipe (CG)
(1) Finishing Plate
(1) Finishing Collar (CG)
(1) 90 Degree Elbow (CG)
Stove Kit 7FSDHASK
Includes all parts in the 7FSSK plus the Draft Hood Adapter
FSDHAG
Combination Offset/Roof Support 7DVCS
Attic Insulation Shield 7DVAIS
7” Charcoal Gray Pipe Rings, (4) 7FSDRG
7” Polished Brass Pipe Rings (4) 7FSDRP
Wall Thimble 942G
NOTE: Direct vent pipe may be used on the Natural
Vent system from the top of the draft hood adapter to
the ceiling.