Vermont Casting DV580, DV360 Indoor Fireplace User Manual


 
38
DV360/580 Series Direct Vent Gas Fireplace
20010667
Troubleshooting the Gas Control System
START
•TURN GAS SUPPLY OFF
• TURN ON/OFF SWITCH
TO CALL FOR HEAT "ON"
POWER TO MODULE
(24V NORMAL)
SPARK ACROSS
IGNITOR SENSOR GAP
YES
YES
YES
• TURN GAS ON
PILOT BURNER LIGHTS?
SPARK STOPS WHEN
PILOT IS LIT?
MAIN BURNER LIGHTS?
SYSTEM RUNS UNTIL
ON/OFF SWITCH IS IN
"OFF" POSITION
TROUBLESHOOTING
ENDS
YES
YES
YES
NO
NO
NO
NO
NO
NO
CHECK: • LINE VOLTAGE (120VAC)
• LOW VOLTAGE TRANSFORMER (19.5 minimum VAC)
• ON/OFF SWITCH
• WIRING CONNECTIONS
UNPLUG IGNITION LEAD
AND CHECK SPARK
AT MODULE
(24VAC normal)
SPARK OK?
• REPLACE MODULE
CHECK IGNITION CABLE GROUND WIRING, CERAMIC INSULATOR
AND GAP. CORRECT AS NECESSARY
CHECK BOOT OF IGNITION CABLE FOR SIGNS OF MELTING OR
BUCKLING. TAKE PROTECTIVE ACTION TO SHIELD
CABLE AND BOOT FROM EXCESSIVE TEMPERATURES.
• CHECK THAT ALL MANUAL GAS VALVES ARE OPEN, SUPPLY TUBING
AND PRESSURES ARE GOOD, AND PILOT BURNER ORIFICE
IS NOT BLOCKED.
• CHECK ELECTRICAL CONNECTIONS BETWEEN MODULE AND
PILOT OPERATOR ON GAS CONTROL.
• CHECK FOR 24VAC ACROSS PV-MVPV TERMINALS ON MODULE IF
VOLTAGE IS OKAY, REPLACE GAS CONTROL IF NOT, REPLACE
MODULE.
NOTE: IF S8600B GOES INTO LOCKOUT, RESET SYSTEM.
• CHECK CONTINUITY OF IGNITION CABLE AND GROUND WIRE.
• CLEAN FLAME ROD
• CHECK ELECTRICAL CONNECTIONS BETWEEN FLAME ROD & MODULE.
• CHECK FOR CRACKED CERAMIC FLAME ROD INSULATOR.
• CHECK THAT PILOT FLAME COVERS FLAME ROD AND IS STEADY BLUE
• ADJUST PILOT FLAME.
• IF PROBLEM PERSISTS, REPLACE MODULE.
• CHECK FOR 24VAC ACROSS MV-MVPV TERMINALS IF NO
VOLTAGE, REPLACE MODULE.
• CHECK ELECTRICAL CONNECTIONS BETWEEN MODULE AND GAS
CONTROL. IF OKAY, REPLACE GAS CONTROL, OR GAS CONTROL
OPERATOR.
NOTE: IF S8600B GOES INTO LOCKOUT, RESET SYSTEM
• CHECK FOR CONTINUITY OF IGNITION CABLE AND GROUND WIRE.
NOTE: IF GROUND IS POOR OR ERRATIC, SHUTDOWN MAY OCCUR
OCCASIONALLY EVEN THOUGH OPERATION IS NORMAL AT THE TIME
OF CHECKOUT.
• CHECK THAT THE PILOT FLAME COVERS FLAME ROD AND IS STEADY
AND BLUE.
• IF CHECKS ARE OKAY, REPLACE MODULE.
NO
YES