Operation
Your First Fire
Read these instructions carefully and familiarize
yourself with the burner controls shown on Page 18.
Locate the pilot assembly, Figure 28. Follow the
lighting instructions on Page 17 exactly.
During the first fire, it is not unusual to smell some odor
associated with new logs, paint and metal being
heated. Odors should dissipate within the first eight to
ten hours, however, you can open a window to provide
fresh air to alleviate the condition.
Pilot and Burner Inspection
Each time you light your heater check that the pilot
flame and burner flame patterns are as shown in
Figures 31 and 32. If flame patterns are incorrect, turn
the heater off. Contact your dealer or a qualified gas
technician for assistance. Do not operate the heater
until the pilot flame is correct.
Follow regular maintenance procedures as described
on Page 20.
Natural
Pilot
LP Pilot
ST673
Fig. 28 Pilot assembly location.
Flame & Temperature Adjustment
RN/RP Models
For units equipped with ‘HI/LO’ valves the flame
adjustment is accomplished by rotating the ‘HI/LO’
adjustment knob located near the center of the gas
control valve. (Fig. 29, 30)
LO
HI
Turn
counterclockwise
to decrease
flame height
Turn clockwise
to increase
flame height
HV102
Fig. 29 Flame adjustment knob for Honeywell Valve.
HI
OFF
PILOT
LO
Turn
counterclockwise
to increase
flame height
Turn clockwise
to decrease
flame height
SIT 630
HV117
Fig. 30 Flame adjustment knob for Eurosit Valve.
Flame Characteristics
It is important to periodically perform a visual check of
the pilot and burner flames. Compare them to the
pictorial illustrated below. (Fig. 31, 32) If the flame
patterns appear abnormal contact a qualified service
provider for service and adjustment.
ST198
Fig. 31 Correct pilot flame appearance.
LG225
Fig. 32 Correct burner flame pattern.