COOLING CAPACITIES AND EFFICIENCIES
50XP 024 3
UNIT
50XP
NOMINAL
TONS
STANDARD
CFM
NET COOLING
CAPACITIES
(Btuh)
EER@A** SEER†
SOUND
RATINGS‡
(dB)
024 2 800 24,000 11.0 13.0 72
030 2-1/2 1000 28,800 11.0 13.0 72
036 3 1100 36,000 11.0 13.0 72
042 3-1/2 1400 41,000 11.0 13.0 72
048 4 1450 45,000 11.0 13.0 78
060 5 1710 57,000 11.0 13.0 78
LEGEND
dB Sound Levels (decibels)
db Dry Bulb
SEER Seasonal Energy Efficiency Ratio
wb Wet Bulb
* Air Conditioning & Refrigeration Institute.
** “A” Conditions- 80°F indoor db/67°F indoor wb & 95°F outdoor db.
Rated in accordance with U.S. Government DOE Department of
Energy) test procedures and/or ARI Standard 210/240-94.
Tested in accordance with ARI Standard 270-95 (not listed in ARI).
NOTES:
1. Ratings are net values, reflecting the effects of circulating fan heat.
Ratings are based on:
Cooling Standard: 80°F db, 67°F wb indoor entering-air tempera-
ture and 95°F db outdoor entering-air temperature.
2. Before purchasing this appliance, read important energy cost and
efficiency information available from your retailer.
Options
(None)
– Wire Grille
AD
– Louvered Grille
BT
– Wire Grille and Vinyl-Coated Condenser
Coil Fin
XT
– Louvered Grille and Vinyl-Coated Con-
denser Coil Fin
CC
– Wire Grille, AL Evaporator and CU/CU
Condenser Coil
AC
– Louvered Grille, AL Evaporator and CU/
CU con
Options
BT
AL evap, vinyl condens
CC
AL evap, CU condens
CU
CU evap & condens
TP
Base unit with tin plated indoor coil
hairpins
TV
TP with vinyl coating on outdoor coil
TC
TP with AL indoor coil & CU/CU out-
door coil
Only used if ordering an option
AL
— Aluminum
CU
— Copper
V-Ph-Hz
3
– 208/230-1-60
5
– 208/230-3-60
Model Number
50XP
– Single
Packaged-Electric
Cooling
Nominal Cooling Capacity
024
– 2 ton
030
– 2.5 ton
036
– 3 ton
042
– 3.5 ton
048
– 4 ton
060
– 5 ton