Burnham V9 Boiler User Manual


 
V9 Series Ratings
& Equipment Listing
8
BurnhamCommercial-Lancaster,PA
www.burnhamcommercial.com
PL81401291000-10/10-4Ms
1. Sufx“S”indicatessteamboiler,“W”indicateswaterboiler.Sufx“G”indicatesgas-red,“O”indicatesoilredand“GO”indicatescombination
gas/oil fired.
2. Boilerratingsarebasedon12.5%CO2onoil;9.7%CO2ongas,and.10in.watercolumnpressureatboilerueoutlet.
3. I=B=Rnetratingsshownarebasedonpipingandpickupallowanceswhichvaryfrom1.333to1.289forsteamand1.15forwater.Consultmanufacturerfor
installations having unusual piping and pick up requirements, such as intermittent system operation, extensive piping systems, etc.
4. TheI=B=RburnercapacityinGPHisbasedonoilhavingaheatvalueof140,000BTUpergallon.
Ratingsshownaboveapplytoaltitudesupto1000feetonoiland2000feetongas.Foraltitudesabovethoseindicated,theratingsshouldbereducedattherate
of4%foreach1000feetaboveabovesealevel.
NOTE: Maximumallowableworkingpressure(MAWP):
Steam:15PSI
Water–USA:80PSI(standardreliefvalveprovidedis50PSI)(30PSIand80PSIreliefvalveoptional)
Water–Canada:45PSI(standardreliefvalveprovidedis45PSI)(30PSIreliefvalveoptional)
STANDARD EQUIPMENT
ALL BOILERS: Sections unassembled, flush insulated jacket, burner mounting plate, burner adapter plate, rear flue outlet damper (top outlet optional), flue
canopy,rearobservationportcover,targetwall(V-903A),andmiscellaneousplugs,bushingandttings,L4006B(lowreholdaquastat).
STEAM TRIM:15PSIsafetyvalve,L404FApressuretrol,gaugeglassassembly,steamgauge
WATER TRIM:50PSIsafetyreliefvalve,L4006Ahighlimit,pressure/temperaturegauge
OIL BOILERS:Flangemountedameretentionoilburnerfurnishedwith2stagefuelunit,primarycontrolanddualoilvalves
GAS BOILERS:FlangemountedgasburnerwithstandardcontrolsmeetingthelatestULrequirements,dualgasvalves,gas-electricignitionwithprovengaspilot,
amerodonJRburner,ultravioletamedetectoronothers,electronicprogrammingcontrolsandcomponentsarefactorywiredinaburnermountedcontrolpanel.
GAS/OIL BURNERS:Flangemountedcombinationgas/oilburnerwithstandardcontrolsmeetinglatestULrequirements,manuallyoperatedfueltransferswitchfor
dual fuel changeover, dual gas valves and oil valves, electric ignition with proven gas pilot on both fuels (direct spark ignition of oil is optional), ultra-violet flame
detector, electronic programming controls and components are factory wired in a burner mounted control panel.
OPTIONAL EQUIPMENT
Assembled sections; completely packaged (includes manual reset
high limit and manual reset low water cutoff); packaged and fire-
tested; top outlet flue damper; tankless heaters; side inspection
tappingswithbrassplugs;30PSIand80PSIsafetyreliefvalves
(water); combustion and hydronic controls to meet special
applicationsincludingF.M.,I.R.I.,andASMECSD-1.
BOILER
MODEL (1) BOILER H.P.
GROSS
OUTPUT
MBH (2)
NET I=B=R RATINGS (2) (3) BURNER INPUT NET
FIREBOX
VOLUME
(CU. FT)
PRESSURE
IN FIREBOX
(IN. WTR.
COLUMN)
I=B=R VENT
DIA. (IN.)
STEAM
WATER
MBH
OIL
(GPH) (4)
GAS
(MBH)
MBH SQ. FT.
V-903A
V-904A
V-905A
V-906A
V-907A
V-908A
V-909A
V-910A
V-911A
V-912A
10.3
14.4
19.3
24.1
28.6
33.2
40.1
45.6
51.2
56.8
347
483
646
808
959
1110
1342
1528
1714
1900
260
362
485
606
719
833
1014
1168
1323
1474
1083
1508
2021
2525
2996
3471
4225
4867
5513
6142
302
420
562
703
834
965
1167
1329
1490
1652
3.1
4.2
5.6
7.0
8.3
9.6
11.6
13.2
14.8
16.4
447
606
808
1010
1198
1386
1674
1905
2136
2367
3.2
4.8
6.4
7.9
9.5
11.0
12.6
14.2
15.7
17.3
.33
.38
.31
.38
.36
.35
.35
.40
.45
.49
7
7
8
8
8
10
10
10
12
12
BOILER
MODEL
NUMBER OF V9-2 TANKLESS*
HEATERS INSTALLED
1 2 3 4
V-903A 6.75 Ñ Ñ Ñ
V-904A 7.5 Ñ Ñ Ñ
V-905A 7.5 Ñ Ñ Ñ
V-906A 7.5 15 Ñ Ñ
V-907A 7.5 15 Ñ Ñ
V-908A 7.5 15 Ñ Ñ
V-909A 7.5 15 22.5 Ñ
V-910A 7.5 15 22.5 Ñ
V-911A 7.5 15 22.5 Ñ
V-912A 7.5 15 22.5 30.0
TANKLESS
HEATER
RATINGS*
(Water and
Steam)
* Ratings are given in
gallons per minute
continuous draw of
water heated from
40°Fto140°Fwith
200°Fboilerwater.
Phone: 1-888-791-3790