SECTION III
INSTALLATION MODEL 329 (FP)
IN SOLID FUEL BURNING FIREPLACES
20"
24"
29-1/2"
Figure 7
7"
24"
6"
(1) The Model 329 (FP) may be installed in a masonry fireplace. The minimum fireplace
dimension must be 24" high, 29-1/2" wide, and 6" deep.
(2) For minimum dimensions for the sidewall and mantel, see Figure 7.
(3) Center the heater in fireplace opening.
(4) NOTE: See “Producing Adequate Ventilation” page 32.
NOTE: The installer of this appliance must mechanically (peel and stick) attach the marking
supplied with this unvented appliance before installing to the inside of the firebox of the solid-fuel
burning fireplace or listed ventless firebox enclosure into which the unvented fireplace insert is
installed. See the example of the marking on page 8 of this manual.
CAUTION: Cutting any sheet-metal parts of the solid-fuel burning fireplace or listed ventless
enclosure in which the unvented fireplace is to be installed is prohibited.
NOTE: “If the factory-built fireplace has no gas access hole(s) provided, an access hole of 1.5 inch
(37.5) diameter or less may be drilled through the lower sides or bottom of the firebox in a proper
workmanlike manner. This access hole must be plugged with non-combustible insulation after the
gas supply line has been installed.”
“Refractory, glass doors, screen rails, screen mesh and solid-fuel log grates (if applicable)
can be removed from the fireplace before installing the unvented fireplace insert.”
“Smoke shelves, shields and baffles may be removed if attached by mechanical fasteners.”
“ Trim panels or surrounds shall not seal ventilation openings in the fireplace.”
NOTE: After the unit is positioned in fireplace, mark the trim panels as follows:
A. Set the side panels in place, flat against the fireplace. Mark down the inside edge of the trim
panel to make a vertical reference line.
LEFT SIDE
RIGHT SIDE
Page 24