New Buck Corporation 329 Indoor Fireplace User Manual


 
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information on previous page.
2. Make sure the manual shutoff valve is fully closed. If equipped with thermostat set to the lowest
setting.
3. Turn off all electrical power to the appliance.
4. Open access panel door located at bottom front of the appliance.
5. Turn control knob clockwise to the full “OFF” position.
When hooking up a Wall Thermostat to valve, remove the Jumper Bar. Do not remove the existing
wires, simply add the wire from the Wall Thermostat to screws (one wire to each screw).
6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you
smell gas, STOP! Follow “B” in the safety informationon the previous page.If you don’t smell
gas, go to the next step.
7. Find Pilot: The pilot is located in front of the rear log and burner on the right hand side of the
appliance. Fully open the manual shutoff valve.
8. Push the ON/OFF toggle switch to “OFF” (rocker switch).
9. Turn gas control knob counterclockwise to the “PILOT” position.Press in gas control
knob for fifteen (15) seconds.
10. With control knob pressed in , push down (in) and release the ignitor button (ignitor button is
located on the left hand side of the front of the appliance). This will light the pilot. If needed, keep
repeating this step until pilot lights.
11. Keep control knob pressed in for (1) one minute after lighting pilot. After (1) minute, release the
gas control knob and it will pop back up. Pilot should remain lit. If pilot goes out, repeat steps 1
through 9.
If the knob does not pop up when released, stop and immediately call your service technician or
gas supplier.
PILOT BURNER
IGNITOR ELECTRODE
THERMOGENERATOR
PILOT
9080706050
ON
OFF
BEFORE INSTALLING THERMOSTAT
REMOVE METAL CONNECTOR
PIEZO
ROCKER SWITCH
BURNER
PILOT ASS'Y
THERMOSTAT
ITT VALVE
THERMO GEN
AUX
P
RE
S
S
TO
R
E
S
E
T
OFF
P
I
L
O
T
O
N
ITT
GENERAL
CONTROLS
PILOT
ADJ
THERMOPILE
CONTROL KNOB
Page 10