New Buck Corporation 34 Indoor Fireplace User Manual


 
LIGHTING INSTRUCTION
1. STOP! Read the safety information on preceding page 15.
2. Make sure manual shutoff valve is fully closed.
3. Turn off all electrical power to the appliance.
4. Open access panel door located at bottom front of the appliance.
5. Turn control knob clockwise to the full “OFF” position.
6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If
you smell gas, STOP! Follow “B” on preceding page in the Safety Information. If you
don’t smell gas, go to the next step.
7. 7. Find Pilot: The pilot is located in front of the rear log and burner on the right hand side
of the appliance. Fully open the manual shutoff valve.
8. Press in and turn gas control knob counterclockwise to the “PILOT” posi-
tion continue pressing in control knob for fifteen (15) seconds.
9. With control knob pressed in, push down (in) and release the ignitor button (ignitor button
is located on the left hand side of the gas control valve) . This will light pilot. If needed,
keep repeating this step until pilot lights.
10. Keep control knob pressed in for one (1) minute after lighting pilot. After one (1) minute,
release control knob and it will pop back up. Pilot should remain lit. If pilot goes out, repeat
steps 1 through 9.
If the knob does not pop up when released, stop and immediately call your service techni-
cian or gas supplier.
“If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call
your services technician or gas supplier.”