New Buck Corporation 261 Stove User Manual


 
DVL CLOSE
CLEARANCE PIPE
CEILING SUPPORT BOX
CEILING
NEW BUCK
CONTEMPORARY CAP
Figure 4.
ROOF
Figure 39.
BUCK STOVE
2. After locating the center of the hole install the ceiling support box, chimney, flashing and
rain cap using listed chimney only. Only use pipe listed in this manual.
CAUTION
REFER TO CHIMNEY MANUFACTURER’S INSTRUCTIONS FOR ASSEMBLY AND
DISASSEMBLY OF CHIMNEY PARTS. BE SURE TO FOLLOW CHIMNEY INSTRUC-
TIONS FOR PROPER CLEARANCES TO COMBUSTIBLE AND PROPER AIR SPACING
REQUIRED.
3. Add additional pipe until both of the following are met:
(a) Chimney pipe is 3 feet higher than roof at the point where it penetrates the roof.
(b) Chimney pipe height is at least 2 feet higher than any part of the roof within 10 feet of
the chimney. (See Page 43 Figure 38.)
4. Next, install a New Buck Cast Collar Part # MA6CHIMCNB to the flue of the heater.
(See Page 40 Figure 34).
5. Using double wall chimney connector, connect the heater to the chimney by following
manufacturer's installation instructions exactly. (See Figure 39.)
NEW BUCK
CAST COLLAR
Part# MA6CHIMCNB
44