New Buck Corporation 261 Stove User Manual


 
HOW TO LOCATE CHIMNEY EXIT, AND INSTALL
B. Vertical Exit using (6" DVL Close Clearance pipe, or Shielded Single wall pipe, and
any Listed 2100° UL 103 HT chimney).
W
ith standard close clearance shield and pipe shield.
NOTE: For minimum clearances (See Page 11, Figure 5).
1. Suspend a plumb bob from the ceiling above the unit so that the weight is hanging in the
center of the flue exit. (A small weight on a string will serve as a plumb bob.) Mark the
ceiling where the string is suspended to locate the center of the chimney hole.
2. After locating the center of the hole, install the ceiling support box, chimney or chimney
connector, flashing, and rain cap per the chimney manufacturer’s instructions, and local
building codes for installation through combustible walls or ceilings.
3. Now connect the stove and ceiling support box using DVL close clearance pipe or
Shielded Single wall pipe. Connect each section per manufacturer’s instructions, and
secure each section to each other using minimum (3) sheet metal screws or rivets.
DVL close clearance pipe or Shielded Single wall pipe is to be connected with (3) sheet
metal screws or rivets to New Buck Cast Collar, after New Buck Cast
Collar Part# MA6CHIMCNB has been attached to stove. ( See Page 11, Figure 6).
10