New Buck Corporation 261 Stove User Manual


 
F. Vertical exit using (6" DVL Close Clearance pipe
with Elbow) into masonry flue.
With standard close clearance shield and pipe shield.
Model 261 minimum clearance to combustibles.
MASONRY CHIMNEY
CLEAN OUT
DOOR
MASONRY
FLUE
LINERS
CEILING
MASONRY CHIMNEY
Figure 14.
DVL CLOSE
CLEARANCE PIPE
Figure 13.
C
C
C
C
BACK
WALL
A
E
B
F
D
G
A
E
B
D
F
BACK WALL
SIDE WALL
PROTECTOR
G
A B C D E F G H
MODEL 261 14” 4" 14" 7" 8" 3" 16" 10"
NEW BUCK
CAST COLLAR
Part# MA6CHIMCNB
NOTE: All clearances are to combustibles with all low clearance shields and single wall pipe
with elbow, and minimum floor protector.NOTE: Floor protector must extend length of
horizontal flue pipe to wall. NOTE: Model 261 comes standard with low clearance shields.
H
Maintain Manufacturers Minimum Clearances
NOTE: