Bryant TZEMT400AB32MAA Thermostat User Manual


 
Gas Furnace - Multistage Mechanical Settings
Press the a. MENU button twice.
Press and hold the two inner buttons for 3 seconds to view b.
Installer Settings.
Scroll down to c. System Settings and press the Select button.
Scroll to d. Mechanical Settings (it is the fi rst option), then press
the Select button.
Scroll down to e. 2nd Stage Heat.
Press the f. + button to change the setting to Y for Yes.
Press the g. Done button 4 times to return to the Home screen.
If your system also has 2nd stage air conditioning, go to step 3D.h.
Menu
button
MENU MODE FAN RUN
75
76 H
74 C
11:15 AM Outside 60
Two inner
buttons
Select button
Scroll
up
Scroll
down
+ button
Done
Mechanical Settings
Select
Type Heatpump
Fan Type Elec
C/O Type w/Cool
2nd Stage Heat N
19A
8
Electric Furnace Mechanical Settings
Press the a. MENU button twice.
Press and hold the two inner buttons for 3 seconds to view b.
Installer Settings.
Scroll down to c. System Settings and press the Select button.
Scroll to d. Mechanical Settings (it is the fi rst option), then press
the Select button.
Scroll down to e. Fan Type.
Press the f. + button to change the setting Electric.
If Single Stage System, setup is complete, press Done.
If Multistage System, continue with steps “g” through “j”.
Scroll down to g. 2nd Stage Heat.
Press the h. + button to change the setting to Y for Yes.
Press the i. Done button to return to the Home screen.
If your system also has 2nd stage air conditioning, go to step 3D.j.
19B
Electric air conditioning - Multistage Mechanical Settings
Press the a. MENU button twice.
Press and hold the two inner buttons for 3 seconds to view b.
Installer Settings.
Scroll down to c. System Settings and press the Select button.
Scroll to d. Mechanical Settings (it is the fi rst option), then press
the Select button.
Scroll down to e. 2nd Stage Cool.
Press the f. + button to change the setting to Y for Yes.
Press the g. Done button 4 times to return to the Home screen.
19D
19C
Heat Pump Mechanical Settings
Press the a. MENU button twice.
Press and hold the two inner buttons for 3 seconds to view b.
Installer Settings.
Scroll down to c. System Settings and press the Select button.
Scroll to d. Mechanical Settings (it is the fi rst option), then press
the Select button.
Scroll to system e. Type.
Press the f. + button to change the setting to Heat Pump.
Scroll down to g. Fan Type.
Press the h. + button to change the setting Electric.
If Coleman, Rheem, or Rudd brand heat pump, scroll to i. C/O
Type and change to With Heat.
If Single Stage System, setup is complete, press Done.
If Multistage System, continue with steps “j” through “n”.
Scroll down to j. 2nd Stage Heat.
Press the k. + button to change the setting to Y for Yes.
Scroll down to l. 2nd Stage Cool.
Press the m. + button to change the setting to Y for Yes.
Press the n. Done button to return to the Home screen.