AC/HP Control should NOT be mounted:
S Close to a window, on an outside wall, or next to a door leading to the
outside.
S Exposed to direct light or heat from a lamp, sun, fireplace, or other
temperatureradiating objects which could cause a false reading.
S Close to or in direct airflow from supply registers and returnair regis-
ters.
S In areas with poor air circulation, such as behind a door or in an al-
cove.
Installer should determine whether control will be installed as singlepiece or
twopiece. In singlepiece configuration, as many as 14 wires may need to run
to wall mounting location for connection to the control. In twopiece
configuration, the Display Module and Equipment Control Module are
connected by two wires.
Install AC/HP Control
ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury or
death.
Before installing AC/HP Control, turn off all power to
equipment. There may be more than 1 power disconnect.
!
WARNING