Bryant R-410A Air Conditioner User Manual


 
5
SPECIFICATIONS Continued
* Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure.
If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70).
The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26. If
other than uncoated (non-plated), 60 or 75°C (140 or 167°F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is
used, consult applicable tables of the NEC (ANSI/NFPA 70).
Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%.
** Fan motor with ball bearings required.
†† See low-ambient controller Installation Instructions for application.
N/A Not Applicable.
NOTE:
Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection.
UNIT SIZE-SERIES 042-A 048-A 060-A
Operating Weight (Lb) 215 217 278
ELECTRICAL
Unit VoltsHertzPhase 208/230-60-1
Operating Voltage Range* 187-253
CompressorRated Load Amps 19.9 24.4 30.1
Locked Rotor Amps 127.0 131.0 172.0
Condenser Fan MotorFull Load Amps 1.10 1.40 1.40
Min Unit Ampacity for Wire Sizing 24.4 26.7 35.9
Min Wire Size (60°C Copper) AWG 10 8 8
Min Wire Size (75°C Copper) AWG 10 10 8
Max Wire Length (Ft) (60°C Copper) 77 97 80
Max Wire Length (Ft) (75°C Copper) 73 59 76
Max Branch Circuit Fuse or
Circuit Breaker Size (Amps) 40 50 60
COMPRESSOR & REFRIGERANT
CompressorType Scroll
Manufacturer Copeland
Temperature & Current Protection Internal Line Break
RefrigerantType Puron® (R-410A)
Amount (Lb) 6.33 6.83 7.93
CONDENSER COIL & FAN
Coil Face Area (Sq Ft) 12.16 12.16 18.3
Fins per In.RowsCircuits 251225122513
Fan MotorHP (PSC) & RPM 1/5 & 825 1/4 & 1100 1/4 & 1100
VoltsHertzPhase 208/230-60-1
Condenser Airow (CFM) 2800 3400 3400
OPTIONAL EQUIPMENT
Support Feet KSASF0101AAA
Coastal Filter KAACF0801MED
Time Delay Relay KAATD0101TDR
Cycle Protector KSACY0101AAA
Crankcase Heater KAACH1201AAA
Start AssistCapacitor/Relay Type KSAHS1501AAA KSAHS1601AAA
Start AssistPTC Type KAACS0201PTC
TXV (Hard Shutoff) KSATX0301HSZ KSATX0401HSZ KSATX0501HSZ
Piston Body KSAPX0101PIS
Filter Drier (Suction Line) (RCD) KH45LG141
Evaporator Freeze Thermostat†† KAAFT0101AAA
Liquid-Line Solenoid Valve KAALS0201LLS
Winter Start Control†† KAAWS0101AAA
Low-Ambient Pressure Switch KSALA0301410
MotorMaster® Control** 32LT660004
Ball Bearing Fan Motor (RCD) HC38GE231 HC40GE232
ThermostatAuto Changeover,
Non-Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool TSTATBBNAC01-B
ThermostatAuto Changeover,
7-Day Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool TSTATBBPAC01-B
Thermidistat Control
Programmable Thermostat with Humidity Control TSTATBBPRH01-B
Builders ThermostatManual Changeover,
Non-Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool TSTATBBBAC01-B
Outdoor Air Temperature Sensor TSTATXXSEN01-B
Backplate for Non-Programmable Thermostat TSTATXXNBP01
Backplate for Programmable Thermostat TSTATXXPBP01
Backplate for Builders Thermostat TSTATXXBBP01
Thermostat Conversion Kit (4 to 5 wire)10 Pack TSTATXXCNV10