Bryant 764A Air Conditioner User Manual


 
UNIT
564A/764A
ELECTRICAL
CHARACTERISTICS
UNIT
WEIGHT
CENTER OF GRAVITY mm [in.]
Lb Kg X Y Z
060
230-1-60, 208/230-3-60,
460-3-60
350 159 355.6 [14.00] 508.0 [20.00] 355.6 [14.00]
LEGEND
NEC National Electrical Code
REQUIRED CLEARANCES TO COMBUSTIBLE
MATERIAL, mm [in.]
Top of Unit ..............................0
Duct Side of Unit ..........................0
Side Opposite Ducts ........................0
Bottom of Unit ............................0
NEC REQUIRED CLEARANCES, mm [in.]
Between Units, Power Entry Side .......1066.8 [42.00]
Unit and Ungrounded Surfaces,
Power Entry Side ................. 914.0 [36.00]
Unit and Block or Concrete Walls and Other
Grounded Surfaces, Power Entry Side ....1066.8 [42.00]
REQUIRED CLEARANCES FOR SERVICING, mm [in.]
Condenser Coil Access Side ............762.0 [30.00]
Power Entry Side
(Except for NEC Requirements) .........762.0 [30.00]
Unit Top ........................914.0 [36.00]
Side Opposite Ducts .................762.0 [30.00]
NOTES:
1. Clearances must be maintained to prevent recirculation of
air from condenser-fan discharge. With the exception of the
condenser coil (914 mm [36 in.]), a removable fence or bar-
ricade requires no clearance.
2. Dimensions are in millimeters. Dimensions in [ ] are in inches.
Fig. 4 Base Unit Dimensions 564A/764A060
—4—