ELECTRICAL DATA (cont.)
569J*16A COOLING WITHOUT POWERED CONVENIENCE OUTLET
V --- Ph --- Hz
VOLTAGE RANGE COMP 1 COMP 2 OFM (ea) POWER SUPPLY
MIN MAX RLA LRA RLA LRA WATTS FLA MCA Fuse
208/230---3---60 187 253 25 164 25 164 325 1.5 60.8 80
460 --- 3 --- 6 0 414 506 12.2 100 12.2 100 325 0.8 29.9 40
575 --- 3 --- 6 0 518 633 9 78 9 78 325 0.7 22.4 30
569J*16A COOLING WITH POWERED CONVENIENCE OUTLET
V --- Ph --- Hz
VOLTAGE RANGE COMP 1 COMP 2 OFM (ea) POWER SUPPLY
MIN MAX RLA LRA RLA LRA WATTS FLA MCA Fuse
208/230---3---60 187 253 25 164 25 164 325 1.5 66.6 90
460 --- 3 --- 6 0 414 506 12.2 100 12.2 100 325 0.8 32.1 40
575 --- 3 --- 6 0 518 633 9 78 9 78 325 0.7 24.1 30
569J*16D COOLING WITHOUT POWERED CONVENIENCE OUTLET
V --- Ph --- Hz
VOLTAGE RANGE COMP 1 COMP 2 OFM (ea) POWER SUPPLY
MIN MAX RLA LRA RLA LRA WATTS FLA MCA Fuse
208/230---3---60 187 253 25 164 25 164 325 1.5 60.7 80
460 --- 3 --- 6 0 414 506 12.2 100 12.2 100 325 0.8 29.8 40
575 --- 3 --- 6 0 518 633 9 78 9 78 325 0.6 22.0 30
569J*16D COOLING WITH POWERED CONVENIENCE OUTLET
V --- Ph --- Hz
VOLTAGE RANGE COMP 1 COMP 2 OFM (ea) POWER SUPPLY
MIN MAX RLA LRA RLA LRA WATTS FLA MCA Fuse
208/230---3---60 187 253 25 164 25 164 325 1.5 65.6 90
460 --- 3 --- 6 0 414 506 12.2 100 12.2 100 325 0.8 32.1 40
575 --- 3 --- 6 0 518 633 9 78 9 78 325 0.7 24.1 30