Bryant 363AAP 361AAN Furnace User Manual


 
—7—
DIMENSIONS—MODEL 363AAP
A96336
DIMENSIONS (In.)
*Filter rack provides transition from duct to opening size.
† Duct sizes are ID dimensions for slipping over filter rack.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (In.)
* Floor may be combustible.
AIR DELIVERY—CFM (Without Filters)
UNIT
SIZE
SHIP
WT
(Lb)
UNIT DIMENSIONS
DUCT SUPPLY
OPENING
FLUE
DIAMETER
SIDE RETURN
OPENING*
END (BOTTOM)
RETURN
OPENING
SIDE RETURN
DUCT SIZE†
END (BOTTOM)
RETURN
DUCT SIZE†WIDTH DEPTH HEIGHT
ABCDE F GHJKLMNP
060210 385 26 42-1/2 54-3/4 24 29 7 17-3/4 37-1/4 24-1/8 29-1/16 20-1/4 38-1/4 24-1/4 38-1/4
UNIT APPLICATION UPFLOW HORIZONTAL
SIDES—Furnace 22
Supply Plenum and Warm-Air Duct Within 6 ft of Furnace 1 1
BACK 22
TOP—Furnace Casing or Plenum 2 2
Horizontal Warm-Air Duct Within 6 ft of Furnace 2 3
BOTTOM 0* 0*
FLUE PIPE—Horizontally or Below Pipe 9 9
Vertically Above Pipe 9 9
FRONT 24 24
UNIT
SIZE
BLOWER
MOTOR
HP SPEED
EXTERNAL STATIC PRESSURE IN. WC
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
060210 3/4 PSC
High 2485 2395 2305 2250 2145 2075 1975 1885 1780 1675
Medium 2195 2125 2060 1990 1915 1860 1785 1700 1620 1525
Low 1640 1590 1540 1515 1460 1410 1350 1275 1190 1075
OIL INLET
3
/
8
IN. DIA
(2 PLCS) BOTH SIDES
ELECTRICAL CONNECTIONS
(TOP)
1
/
2
IN. DIA BOTH SIDES
(BOTTOM)
7
/
8
IN. DIA BOTH SIDES
11
15
/
16
12
1
/
16
1
1
2
FLUE
DIAMETER
F
B
EM
A
D
J
N
C
B
G
K
H
E
L
P
ALTERNATE OIL INLET
THROUGH SLOTS
REAR VIEW
CLEANOUT
PORTS
END
RETURN
AIR DUCT
CONTROL
BOX
SIDE RETURN
AIR DUCT
CLEANOUT PORTS
CLEANOUT PORTS