Bryant 363AAP 361AAN Furnace User Manual


 
—4—
MODEL 362AAN LOW-BOY OIL FURNACE
A96358
The 362AAN Furnace is designed for top performance to provide years of reli-
able, comfortable home heating.
The 362AAN is a Low-Boy style oil furnace that can be installed in limited over-
head areas for greater application coverage. The heat exchanger is backed by a
Limited Lifetime Warranty.
FEATURES
LOW-BOY CABINET STYLE
—The 362AAN allows easy installation in low over-
head areas such as crawlspaces and sub-basements.
HEAT EXCHANGER
—The stainless steel primary and aluminized steel second-
ary heat exchangers are designed for outstanding reliability backed by a Limited
Lifetime Warranty. The heat exchanger utilizes crimped seams instead of welds
for corrosion resistance. All internal surfaces are accessible for any field mainte-
nance without removing the heat exchanger.
CLEANOUT PORTS
—Allow easy cleaning of secondary heat exchanger tubes
without disassembly of the furnace or heat exchanger.
CONTROLS
—The Beckett oil burner is equipped with an electronic primary relay
for added reliability. Integrated fan timer control board with low-voltage terminal
strip and 40-va transformer make air conditioning installation easy.
HEAVY DUTY BLOWER
—Blower motors are PSC type and 3 speed. The direct-
drive blowers eliminate belt adjustments in the field. The constant low-speed
blower switch provides air circulation during “off” cycles for indoor air filtration.
DURABLE CABINET
—The casing is constructed of prepainted steel for years of
attractiveness. Filter provided with each furnace.
* Capacity and AFUE in accordance with U.S. Government DOE test procedures.
Permissible limits of the voltage range at which the unit will operate satisfactorily.
Length shown is measured 1 way along wire path between unit and service panel for maximum 2% voltage drop.
** Time-delay fuse is recommended.
ICS—Isolated Combustion System
UNIT SIZE 036105 048125 060155
RATINGS AND PERFORMANCE
Firing Rate 0.76 0.90 1.12
Input (Btuh) 105,000 125,000 154,000
Heating Capacity (Btuh)* 85,000 100,000 125,000
AFUE %* ICS 80.3 82.5 81.0
Oil Pump Stages 1
Heating Temperature Rise
°
F 55—85
Recommended Heating Blower Speed Medium Medium High
Cooling CFM @ 0.5-in. wc Static Pressure 1550 1630 1800
Heating CFM @ 0.2-in. wc Static Pressure 1335 1675 1960
ELECTRICAL
Unit Volts—Hertz—Phase 115—60—1
Operating Voltage Range† 104—127
Rated Load Amps 12.55 15.65 16.15
Minimum Ampacity for Wire Sizing 14 18 19
Minimum Wire Size AWG 14 12 12
Maximum Wire Length (Ft)‡ 26 32 30
Maximum Fuse Size (Amps)** 15 20 20
Control Transformer (24v) 40va
External Control Power Available Heating 35va
Cooling 35va
Burner Model (3450 RPM) Beckett AFG
BLOWER DATA
Motor HP 1/3 1/2 3/4
Blower Wheel Size (In.) 12 x 9 12 x 9 12 x 12
Blower Motor Speed and Type 1075 PSC Direct
Filter Quantity and Size (1) 21-1/4 x 21-1/4 x 1