Bryant 363AAP 361AAN Furnace User Manual


 
—6—
MODEL 363AAP UPFLOW/HORIZONTAL OIL FURNACE
A93213
The 363AAP Furnace is designed for top performance to provide years of reli-
able, comfortable home heating. This furnace is also designed to meet the need
for large residential and light commercial markets.
The 363AAP is a large capacity upflow/horizontal oil furnace that can be installed
upflow, horizontal right, or horizontal left for greater application coverage. The flue
exits the rear of the furnace. The heat exchanger is backed by a Limited Lifetime
Warranty.
FEATURES
INSTALLATION FLEXIBILITY
—The 363AAP installs in either upflow, horizontal
right, or horizontal left orientation for greater application coverage and installation
flexibility.
HEAT EXCHANGER
—The stainless steel primary and aluminized steel second-
ary heat exchangers are designed for outstanding reliability backed by a Limited
Lifetime Warranty. The heat exchanger utilizes crimped seams instead of welds
for corrosion resistance. All internal surfaces are accessible for any field mainte-
nance without removing the heat exchanger.
CONTROLS
—The Beckett oil burner is equipped with an electronic primary relay
for added reliability. Integrated fan timer control board with low-voltage terminal
strip and 40-va transformer make air conditioning installation easy.
HEAVY DUTY BLOWER
—Blower motors are PSC type and 3 speed. The direct-
drive blowers eliminate belt adjustments in the field. The constant low-speed
blower switch provides air circulation during “off” cycles for indoor air filtration.
DURABLE CABINET
—The casing is constructed of prepainted steel for years of
attractiveness. Filter and frame are provided with each furnace.
* Capacity and AFUE in accordance with U.S. Government DOE test procedures.
Permissible limits of the voltage range at which the unit will operate satisfactorily.
Length shown is measured 1 way along wire path between unit and service panel for maximum 2% voltage drop.
** Time-delay fuse is recommended.
ICS—Isolated Combustion System
UNIT SIZE 060210
RATINGS AND PERFORMANCE
Firing Rate 1.50
Input (Btuh) 210,000
Heating Capacity (Btuh)* 170,000
AFUE %* ICS 81.2
Oil Pump Stages 2
Heating Temp Rise
°
F 70—100
Recommended Heating Blower Speed Medium
Cooling CFM @ 0.5-in. wc Static Pressure 2145
Heating CFM @ 0.2-in. wc Static Pressure 2125
ELECTRICAL
Unit Volts—Hertz—Phase 115—60—1
Operating Voltage Range† 104—127
Rated Load Amps 16.15
Minimum Ampacity for Wire Sizing 19
Minimum Wire Size AWG 12
Maximum Wire Length (Ft)‡ 30
Maximum Fuse Size (Amps)** 20
Control Transformer (24v) 40va
External Control Power Available Heating 35va
Cooling 35va
Burner Model (3450 RPM) Beckett AFG
BLOWER DATA
Motor HP 3/4
Blower Wheel Size (In.) 12 x 12
Blower Motor Speed and Type 1075 PSC Direct
Filter Quantity and Size (1) 24-1/2 x 38-1/4 x 1