—5—
DIMENSIONS—MODEL 362AAN
A96309
DIMENSIONS (In.)
*Flue pipe may be reduced to 5-in. diameter on 105 and 125 sizes for vent sizing.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (In.)
* Floor may be combustible.
AIR DELIVERY—CFM (Without Filters)
UNIT
SIZE
SHIP.
WT (Lb)
UNIT DIMENSIONS
DUCT SUPPLY OPENING
FLUE
DIAMETER RETURN DUCTWIDTH DEPTH HEIGHT
ABCDEF GH
036105 248 22 52 33 20 17-1/4 6* 20 18
048125 269 22 57 33 20 22-1/4 6* 20 18
060155 278 22 57 33 20 22-1/4 6* 20 18
UNIT APPLICATION LOW-BOY
SIDES—Furnace 0
Supply Plenum and Warm-Air Duct Within 6 ft of Furnace 1
BACK 0
TOP—Furnace Casing or Plenum 2
Horizontal Warm-Air Duct Within 6 ft of Furnace 2
BOTTOM 0*
FLUE PIPE—Horizontally or Below Pipe 4
Vertically Above Pipe 8
FRONT 8
UNIT
SIZE
BLOWER
MOTOR
HP SPEED
EXTERNAL STATIC PRESSURE IN. WC
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
036105 1/3 PSC
High 1795 1735 1675 1605 1550 1485 1425 1350 1275 1220
Medium 1365 1335 1305 1275 1255 1215 1155 1105 1050 985
Low 995 965 945 925 900 870 825 775 725 670
048125 1/2 PSC
High 1905 1845 1770 1695 1630 1565 1490 1425 1325 1220
Medium 1750 1675 1620 1560 1500 1440 1370 1305 1235 1130
Low 1390 1350 1305 1260 1220 1180 1120 1060 985 880
060155 3/4 PSC
High 2025 1960 1905 1850 1800 1655 1575 1500 1415 1315
Medium 1885 1825 1760 1705 1640 1565 1500 1430 1350 1265
Low 1555 1490 1445 1410 1350 1280 1230 1155 1085 1005
INSULATION
INTERMEDIATE
PANEL
FILTER
B
A
G
D
ELECTRICAL
CONNECTIONS
OIL INLET
F
12
1
⁄16″
EH
1″
INSULATION
PARTITION
PANEL
SUPPLY
DUCT
CLEAN-OUT PORTS
RETURN
DUCT
1″
3″
C