Bryant 213R Heat Pump User Manual


 
7
ELECTRICAL DATA
(VOLTAGE)
UNIT SIZE
--- SERIES
V/PH
OPER VOLTS* COMPR FAN
MCA
MIN
WIRE
SIZE{
MIN
WIRE
SIZE{
MAX
LENGTH
(FT)}
MAX
LENGTH
(FT)}
MAX
FUSE**
or CKT
BRK
AMPS
MAX MIN LRA RLA FLA 60° C 75° C 60° C 75° C
(N) 018---A
208/230/1 253 187
41 9.0 0.5 11.70 14 14 166 158 20
(N) 024---A 54 11.3 0.8 14.80 14 14 131 125 25
(N) 030---A 72.5 14.8 0.8 19.20 12 12 161 154 30
(N) 036---A 88 17.0 0.9 22.10 12 12 140 133 35
(N) 042---A 104 21.2 0.9 27.40 10 10 181 172 40
(N) 048---A 137 21.2 1.2 27.60 10 10 179 170 40
(N) 060---A 148 28.9 1.2 37.30 8 8 207 197 60
(P) 030---A
208/230/3 253 197
63 10.4 0.75 13.75 14 14 66 63 20
(P) 036---A 77 11.3 0.9 15.03 12 12 96 92 25
(P) 042---A 88 13.4 0.9 17.65 12 12 82 78 25
(P) 048---A 91 13.78 1.2 18.43 10 10 125 119 30
(P) 060---A 123 18.7 1.2 24.58 8 10 146 89 35
(E) 036---A
460/3 506 414
39 5.5 0.5 7.38 14 14 247 235 15
(E) 042---A 44 6.4 0.5 8.50 14 14 214 203 15
(E) 048---A 46 7.1 0.6 9.41 14 14 193 184 15
(E) 060---A 62 8.6 0.6 11.35 14 14 160 152 15
* Permissible limits o f the voltage range at which the unit will operate satisfactorily
{ If wire is applied at ambient greater than 30° C(86° F), con sult table 310--- 16 of the NEC (ANSI/NFPA 70). Th e ampacity of non---metal lic---sheathed cable
(NM), trade name ROMEX, shall be that of 60° C (140° F) conditions, per the NEC (ANSI/NFPA 70) Article 336---26. If other than uncoated (no---plated), 60
or 75° C (140 or 167° C) insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) i s used, consult applicable tables
of the NEC (ANSI/NFPA 70).
} Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%.
** Time---Delay fuse.
FLA --- Full Load Amps
LRA --- Locked Rotor Amps
MCA --- Minimum Circuit Amps
RLA --- Rated Load Amps
NOTE: Control circuit is 24---V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All
motors/compressors contain internal overload protection.
A--WEIGHTED SOUND POWER (DBA)
UNIT SIZE --- SERIES
STANDARD
RATING
TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)
125 250 500 1000 2000 4000 8000
018---A 75 52 59.5 64.5 71 67 61.5 54.5
024---A 76 52.5 63.5 69.5 72 67.5 64.5 59.5
030---A 76 52 64 70 71 68 66.5 65
036---A 76 53 69 66.5 69.5 66.5 63.5 62
042---A 76 57 65 68 72.5 67.5 64 59
048---A 76 57.5 65 68 70.5 69 64 60.5
060---A 77 61 62.5 70 72.5 70 67 60
A--WEIGHTED SOUND POWER (DBA) WITH SOUND HOOD
UNIT SIZE --- SERIES
STANDARD
RATING
TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)
125 250 500 1000 2000 4000 8000
018---A 74 52.0 59.5 64.0 68.0 64.0 60.0 52.5
024---A 75 53.5 63.0 69.0 70.5 66.5 64.0 58.5
030---A 75 53.0 64.5 69.5 70.5 67.5 64.5 60.5
036---A 75 54.0 68.5 65.5 68.0 65.0 62.0 57.5
042---A 76 58.0 64.5 67.0 71.0 65.5 61.0 54.5
048---A 75 58.0 64.0 68.0 69.0 65.5 60.5 55.5
060---A 75 59.5 61.5 67.5 70.0 68.0 64.0 57.5
CHARGING SUBCOOLING (TXV --TYPE EXPANSION DEVI CE)
UNIT SIZE---SERIES REQUIRED SUBCOOLING (_F)
018---A 11
024---A 11
030---A 9
036---A 11
042---A 13
048---A 13
060---A 11
213R