DETAILED COOLING CAPACITIES -- CONTINUED
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES deg F
75 85 95 105 115 125
CFM EWB
Capacity
MBtuh†
Total
System
KW**
Capacity
MBtuh†
Total
System
KW**
Capacity
MBtuh†
Total
System
KW**
Capacity
MBtuh†
Total
System
KW**
Capacity
MBtuh†
Total
System
KW**
Capacity
MBtuh†
Total
System
KW**
Total
Sens
Total
Sens
Total
Sens
Total
Sens
Total
Sens
Total
Sens
213RNA060---A OutdoorSection With FC4DNF060 Indoor Section
1750
72 69.61 35.82 4.46 67.00 34.80 4.88 64.31 33.76 5.34 61.53 32.71 5.85 58.62 31.62 6.41 55.59 30.48 7.02
67 63.45 44.44 4.39 61.04 43.40 4.81 58.55 42.34 5.27 55.98 41.25 5.78 53.30 40.13 6.33 50.49 38.96 6.93
63 58.99 42.98 4.34 56.74 41.94 4.76 54.40 40.87 5.21 51.98 39.77 5.72 49.46 38.64 6.27 46.83 37.46 6.87
62 57.89 52.98 4.33 55.72 51.90 4.74 53.47 50.76 5.20 51.16 49.56 5.71 48.78 48.25 6.26 46.47 46.47 6.87
57 56.07 56.07 4.31 54.33 54.33 4.73 52.50 52.50 5.19 50.59 50.59 5.70 48.58 48.58 6.26 46.47 46.47 6.87
2000
72 70.84 37.47 4.56 68.11 36.44 4.98 65.32 35.40 5.44 62.44 34.33 5.95 59.43 33.22 6.51 56.30 32.08 7.12
67 64.59 47.19 4.49 62.08 46.14 4.91 59.50 45.06 5.36 56.84 43.96 5.87 54.05 42.81 6.43 51.16 41.61 7.03
63 60.09 45.56 4.44 57.75 44.51 4.85 55.31 43.42 5.31 52.80 42.30 5.82 50.19 41.14 6.37 47.48 39.94 6.97
62 59.16 56.66 4.43 56.93 55.47 4.84 54.66 54.15 5.30 52.43 52.43 5.81 50.30 50.30 6.37 48.06 48.06 6.98
57 58.28 58.28 4.42 56.43 56.43 4.84 54.48 54.48 5.30 52.44 52.44 5.81 50.31 50.31 6.37 48.06 48.06 6.98
2250
72 71.75 39.04 4.66 68.93 38.00 5.07 66.06 36.95 5.53 63.10 35.87 6.05 60.01 34.75 6.61 56.79 33.60 7.21
67 65.44 49.83 4.58 62.86 48.76 5.00 60.20 47.66 5.46 57.46 46.53 5.97 54.61 45.35 6.52 51.65 44.13 7.13
63 60.91 48.02 4.53 58.49 46.94 4.95 55.99 45.83 5.40 53.41 44.69 5.91 50.74 43.50 6.46 47.96 42.27 7.06
62 60.29 59.79 4.53 58.14 58.14 4.94 56.08 56.08 5.41 53.95 53.95 5.92 51.71 51.71 6.48 49.36 49.36 7.09
57 60.11 60.11 4.53 58.14 58.14 4.94 56.09 56.09 5.41 53.95 53.95 5.92 51.72 51.72 6.48 49.36 49.36 7.09
Cooling IndoorModel Capacity Power Furnace M odel
*FC4DN(F,B)060 1.00 1.00
FK4DNB006 0.98 0.97
CAR**6024A** 0.97 0.97 315(A,J)AV066135
CSRH*6012A** 0.97 0.97 315(A,J)AV066135
CAR**6024A** 0.97 0.97 315(A,J)AV066155
CNRH*6024A** 0.97 0.97 315(A,J)AV066155
CNRV*6024A** 0.97 0.97 315(A,J)AV066155
CSRH*6012A** 0.97 0.97 315(A,J)AV066155
NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240---94. If additional tubing length and/or
indoor unit is located above outdoor unit, a slight variation in capacity may occur.
{ Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
} Sensible capacities shown are based on 80_F(27_C) entering air at the indoor coil. For sensible capacities at other than 80_F(27_C), deduct 835 Btuh
(245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80_F(27_C), or add 835 Btuh (245 kW) p er 1000 CFM (480 L/S) of indoor coil air
per degree above 80_F(27_C).
** System kw is total of indoor and outdoor unit kilowatts.
{{ At TVA rating indoor condition (75_F edb/63_F ewb). All other indoor air temperatures are at 80_F edb.
EWB — Entering Wet Bulb