Breckwell P2000I Stove User Manual


 
When your stove acts out of the ordinary, the first reaction is to call for help. This guide may save time and money by enabling you to solve
simple problems yourself. Problems can be caused by to only five factors: 1) poor fuel; 2) poor operation or maintenance; 3) poor
installation; 4) component failure; 5) factory defect. You can usually solve those problems related to 1 and 2. Your dealer can solve
problems relating to 3, 4 and 5. Refer to figures 26, 27, and 29 to help locate indicated parts.
STOVE SHUTS OFF AND THE # 2 LIGHT FLASHES
Possible Causes: Possible Remedies: (Unplug stove first when possible)
1. Airflow switch hose or stove attachment pipes for hose are
blocked.
Unhook air hose from the air switch and blow through it. If air flows
freely, the hose and tube are fine. If air will not flow throw the hose,
use a wire coat hanger to clear the blockage.
2. The air inlet, burnpot, interior combustion air chambers,
combustion blower, or exhaust pipe are blocked with ash or
foreign material.
Follow all cleaning procedures in the maintenance section of the
owner’s manual.
3. The firebox is not properly sealed.
Make sure the door is closed and that the gasket is in good shape.
If the ash door has a latch, make sure the ash door is properly
latched and the gasket is sealing good. If the stove has just a small
hole for the ashes to fall through under the burnpot, make sure the
slider plate is in place to seal off the firebox floor.
4. Vent pipe is incorrectly installed.
Check to make sure vent pipe installation meets criteria in owner’s
manual.
5. The airflow switch wire connections are bad.
Check the connectors that attach the gray wires to the air switch.
6. The gray wires are pulled loose at the Molex connector on the
wiring harness.
Check to see if the gray wires are loose at the Molex connector.
7. Combustion blower failure.
With the stove on, check to see if the combustion blower is running.
If it is not, you will need to check for power going to the combustion
blower. It should be a full current. If there is power, the blower is
bad. If there is not, see #8.
8. Control board not sending power to combustion blower.
If there is no current going to the combustion blower, check all wire
connections. If all wires are properly connected, you have a bad
control board.
9. Control board not sending power to air switch.
There should be a 5-volt current (approximately) going to the air
switch after the stove has been on for 30 seconds.
10. Air switch has failed (very rare).
To test the air switch, you will need to disconnect the air hose from
the body of the stove. With the other end still attached to the air
switch, very gently suck on the loose end of the hose (you may want
to remove the hose entirely off the stove and the air switch first and
make sure it is clear). If you hear a click, the air switch is working.
BE CAREFUL TOO MUCH VACUUM CAN DAMAGE THE AIR
SWITCH.
TROUBLESHOOTING GUIDE
23