Bradley Smoker TDB3104 Plumbing Product User Manual


 
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204 Installation Instructions
Bradley Corporation • 215-1470 Rev. H; EN 06-915
16 2/8/07
3/8" TUBE FROM
SPRAYHEAD
THERMOSTATIC
MIXING VALVE
VALVE
BRACKET
VOLUME
CONTROL
FLEXIBLE
HOSING
COLD SUPPLY
PEDESTAL
REAR
FLEXIBLE
HOSING
HOT SUPPLY
1/8" TUBING TO
ACTUATOR
VALVE AND TUBING CONNECTIONS - AIR METERING VALVE OPTION
NOTE: FLUSH SUPPLY LINES BEFORE MAKING CONNECTIONS.
DO NOT APPLY PIPE SEALANT TO COMPRESSION FITTINGS.
Figure 11b
Installation Instructions continued . . .
Step 5: Valve and Tubing Connections
NOTE: Flush supply lines before making connections.
1. Attach hot and cold flexible supply lines to mixing valve assembly, two places (see Figure 11a
and Figure 11b).
2. Hang valve assembly on pedestal valve bracket.
3. Use wire tie to secure valving to valve bracket.