Bradley Smoker MG-2/BIR3 Plumbing Product User Manual


 
Express® Lavatory System - MG Series with Battery Infrared Control
MG-2/BIR3 Installation Instructions
8 8/23/07 Bradley Corporation • 215-1510 Rev. D; ECN 07-815
Installation Instructions continued . . .
Step 3: Mount frame to wall
1. Loosen, but do not remove the bottom three access panel screws.
2. Remove the two top access panel screws and washers securing the access panel to the frame and
remove the access panel (see Figure 3).
3. Position the frame with Terreon® End Caps attached, against the wall, ensuring that it is level.
IMPORTANT: Anchoring the frame to a wall that is not flat may cause the frame to
bend. If necessary, install shims to compensate for wall distortion.
4. Ensure that the back of the frame is flat against the wall. If wall is not flat, insert shims behind
the frame to ensure that it will not bend when anchored.
5. Once you have positioned the frame such that it is level and flat against the wall or shimmed, use
the 3/8" bolts and washers to mount the frame to the wall.
Figure 3
FRAME
STAINLESS STEEL
ACCESS PANEL
3/8" BOLTS AND WASHERS
(6) PLACES
TERREON®
END CAP
RIGHT
TERREON®
END CAP
LEFT
1/4" - 20 SCREWS
AND FINISHING
WASHERS
(5) PLACES
FRONT VIEW