GENERAL OPERATION
TO FILL THE WATER HEATER
1. Close the water heater drain valve using a standard screwdriver.
2. Open the cold water supply shut-off valve.
3. Open several hot water faucets to allow air to escape from the system.
4. When a steady stream of water flows from the faucets, the water heater is
filled. Close the faucets and check for water leaks at the water heater drain
valve, combination temperature and pressure relief valve and the hot and cold-
water connections.
TO DRAIN THE WATER HEATER
Should it become necessary to completely drain the water heater, make sure you
follow the steps below:
1. Shut off the gas supply to the water heater.
2. Turn off/disconnect all electric power to the water heater.
3. Close the cold water supply shut-off valve.
4. Open the drain valve on the water heater using a standard screwdriver. The
drain valve has threads on the end that will allow the connection of a standard
hose coupling.
5. Open a hot water faucet to allow air to enter the system.
To refill the water heater, refer to “To Fill the Water Heater.”
WARNING
Water heaters are heat-producing appliances. To avoid damage or injury
there must be no materials stored against the water heater or vent-air intake
system, and proper care must be taken to avoid unnecessary contact
(especially by children) with the water heater and vent-air intake system.
UNDER NO CIRCUMSTANCES MUST FLAMMABLE MATERIALS, SUCH
AS GASOLINE OR PAINT THINNER BE USED OR STORED IN THE
VICINITY OF THIS WATER HEATER, VENT-AIR INTAKE SYSTEM OR IN
ANY LOCATION FROM WHICH FUMES COULD REACH THE WATER
HEATER OR VENT-AIR INTAKE SYSTEM.
INTERNET VERSION FOR REFERENCE ONLY